Tap water quality report

Graystone S/D

EPA monitoring tested this supplier for 14 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
12
detected
53
people served
0
health-based violations
Water source
SWP
Ownership
Private
Counties served
Wake

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
13
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2014-10-01
MR Monitoring Resolved 2014-10-01
MR Monitoring Resolved 2014-10-01
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31
MR Monitoring Resolved 2014-01-01 → 2014-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
18.125 µg/L
No EPA limit set
worst single sample: 18.2 µg/L
6/6 SYR4 2014–2019
Bromoform
4.9 µg/L
No EPA limit set
worst single sample: 5 µg/L
6/6 SYR4 2014–2019
Chloroform
18.95 µg/L
No EPA limit set
worst single sample: 20.4 µg/L
6/6 SYR4 2014–2019
Dibromoacetic Acid
7.15 µg/L
No EPA limit set
worst single sample: 8.4 µg/L
6/6 SYR4 2014–2019
Dibromochloromethane
16.9 µg/L
No EPA limit set
worst single sample: 17.2 µg/L
6/6 SYR4 2014–2019
Dichloroacetic Acid
13.75 µg/L
No EPA limit set
worst single sample: 14 µg/L
6/6 SYR4 2014–2019
TTHM
53.5 µg/L 67%
of the EPA limit 80 µg/L
worst single sample: 54 µg/L
6/6 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
21.5 µg/L 36%
of the EPA limit 60 µg/L
worst single sample: 22 µg/L
6/6 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2025
Trichloroacetic Acid
4.16 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
5/6 SYR4 2014–2019
Copper
56.75 µg/L 4.4%
of the EPA limit 1300 µg/L
worst single sample: 57 µg/L
2/16 SYR4 2014–2017
Monobromoacetic Acid
1 µg/L
No EPA limit set
1/6 SYR4 2014–2019
2 contaminants tested, none detected
LeadMonochloroacetic Acid

Utility contact

Contact
WAGNER, MICHAEL
Phone
919-567-3911
Email
[email protected]

Frequently asked questions about Graystone S/D

Is Graystone S/D tap water safe to drink?

EPA monitoring detected 12 contaminants in Graystone S/D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Graystone S/D's water?

EPA monitoring detected Bromodichloromethane, Bromoform, Chloroform, Dibromoacetic Acid, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Graystone S/D serve?

Graystone S/D reports serving 53 people in North Carolina, per its EPA record.

Has Graystone S/D had any water quality violations?

The EPA has 13 violations on file for Graystone S/D, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.