Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| RPT | Monitoring | Resolved | 2017-02-11 |
| RPT | Monitoring | Resolved | 2017-02-11 |
| RPT | Monitoring | Resolved | 2017-02-11 |
| RPT | Monitoring | Resolved | 2017-02-11 |
| RPT | Monitoring | Resolved | 2017-02-11 |
| MR | Monitoring | Resolved | 2014-10-01 |
| MR | Monitoring | Resolved | 2014-10-01 |
| MR | Monitoring | Resolved | 2014-10-01 |
| Other | Monitoring | Resolved | 2012-07-01 |
| Other | Monitoring | Resolved | 2012-07-01 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| PFOS | 0.0054 µg/L | 3/4 | 2024 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 370 µg/L 28% of the EPA limit 1300 µg/L
worst single sample: 5760 µg/L | 444/522 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 45.35 µg/L 76% of the EPA limit 60 µg/L
worst single sample: 69.6 µg/L | 134/134 | SYR4 | 2012–2019 |
| TTHM | 69.45 µg/L 87% of the EPA limit 80 µg/L
worst single sample: 102.7 µg/L | 132/134 | SYR4 | 2012–2019 |
| Chloroform | 44.9 µg/L No EPA limit set
worst single sample: 59 µg/L | 103/103 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 19.9 µg/L No EPA limit set
worst single sample: 29 µg/L | 103/103 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 19 µg/L No EPA limit set
worst single sample: 21 µg/L | 102/103 | SYR4 | 2013–2019 |
| Bromodichloromethane | 19 µg/L No EPA limit set
worst single sample: 24 µg/L | 100/100 | SYR4 | 2013–2019 |
| Dibromochloromethane | 8 µg/L No EPA limit set
worst single sample: 9 µg/L | 95/100 | SYR4 | 2013–2019 |
| Lead | 127.6 µg/L 851% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 851 µg/L | 73/522 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 3.35 µg/L No EPA limit set
worst single sample: 8 µg/L | 54/103 | SYR4 | 2013–2019 |
| Monobromoacetic Acid | 16.55 µg/L No EPA limit set
worst single sample: 18 µg/L | 30/103 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 22/22 | LCR | 2025 |
| Monochloroacetic Acid | 15.7 µg/L No EPA limit set
worst single sample: 22 µg/L | 19/103 | SYR4 | 2013–2019 |
| Fluoride | 878 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 950 µg/L | 9/9 | SYR4 | 2012–2019 |
| Barium | 23.9 µg/L 1.2% of the EPA limit 2000 µg/L
worst single sample: 24 µg/L | 2/9 | SYR4 | 2012–2019 |
| Bromoform | 1 µg/L No EPA limit set | 1/103 | SYR4 | 2013–2019 |
93 contaminants tested, none detected
Utility contact
Frequently asked questions about Roanoke Rapids Sanitary Dist
Is Roanoke Rapids Sanitary Dist tap water safe to drink?
EPA monitoring detected 17 contaminants in Roanoke Rapids Sanitary Dist's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Roanoke Rapids Sanitary Dist's water?
EPA monitoring detected Copper, Total Haloacetic Acids (HAA5), TTHM, Chloroform, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Roanoke Rapids Sanitary Dist serve?
Roanoke Rapids Sanitary Dist reports serving 15,630 people in North Carolina, per its EPA record.
Has Roanoke Rapids Sanitary Dist had any water quality violations?
The EPA has 38 violations on file for Roanoke Rapids Sanitary Dist, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.