← North Carolina

Tap water quality report

Warrenton, Town of

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
2,250
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Warren

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
60
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2021-01-01
MR Monitoring Resolved 2021-01-01
MR Monitoring Resolved 2021-01-01
Other Monitoring Resolved 2011-07-01
Other Monitoring Resolved 2007-10-01
Other Monitoring Resolved 2007-10-01
Other Monitoring Resolved 2007-09-26
Other Monitoring Resolved 2007-09-26
Other Monitoring Resolved 2007-07-01
Other Monitoring Resolved 2007-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
45.75 µg/L 76%
of the EPA limit 60 µg/L
worst single sample: 51 µg/L
26/26 SYR4 2012–2019
TTHM
70.6 µg/L 88%
of the EPA limit 80 µg/L
worst single sample: 79 µg/L
25/26 SYR4 2012–2019
Copper
890.2 µg/L 68%
of the EPA limit 1300 µg/L
worst single sample: 1141 µg/L
20/20 SYR4 2014–2017
Bromodichloromethane
25 µg/L
No EPA limit set
19/19 SYR4 2013–2019
Chloroform
49.2 µg/L
No EPA limit set
worst single sample: 60 µg/L
19/19 SYR4 2013–2019
Dibromochloromethane
8.2 µg/L
No EPA limit set
worst single sample: 10 µg/L
19/19 SYR4 2013–2019
Dichloroacetic Acid
22.3 µg/L
No EPA limit set
worst single sample: 25 µg/L
19/19 SYR4 2013–2019
Trichloroacetic Acid
21.3 µg/L
No EPA limit set
worst single sample: 24 µg/L
19/19 SYR4 2013–2019
Dibromoacetic Acid
3.5 µg/L
No EPA limit set
worst single sample: 4 µg/L
11/19 SYR4 2013–2019
Monochloroacetic Acid
5.7 µg/L
No EPA limit set
worst single sample: 6 µg/L
4/19 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR 2025
Monobromoacetic Acid
21.3 µg/L
No EPA limit set
worst single sample: 22 µg/L
3/19 SYR4 2013–2019
Lead
23 µg/L 153%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 24 µg/L
2/20 SYR4 2014–2017
1 contaminants tested, none detected
Bromoform

Utility contact

Contact
ELLIOTT, BRANDON T.
Phone
252-257-1776
Email
[email protected]

Frequently asked questions about Warrenton, Town of

Is Warrenton, Town of tap water safe to drink?

EPA monitoring detected 13 contaminants in Warrenton, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Warrenton, Town of's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Copper, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Warrenton, Town of serve?

Warrenton, Town of reports serving 2,250 people in North Carolina, per its EPA record.

Has Warrenton, Town of had any water quality violations?

The EPA has 60 violations on file for Warrenton, Town of, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.