Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2012-01-01 → 2012-01-31 |
| TT | Health-based | Resolved | 2012-01-01 → 2012-01-31 |
| TT | Health-based | Resolved | 2012-01-01 → 2012-01-31 |
| TT | Health-based | Resolved | 2012-01-01 → 2012-01-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| TT | Health-based | Resolved | 2011-12-01 → 2011-12-31 |
| MCL | Health-based | Resolved | 2004-04-01 → 2004-06-30 |
| MCL | Health-based | Resolved | 2004-04-01 → 2004-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 80.67 µg/L 101% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 108.7 µg/L | 128/128 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 69.3 µg/L 116% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 105 µg/L | 128/128 | SYR4 | 2012–2019 |
| Bromodichloromethane | 8.81 µg/L No EPA limit set
worst single sample: 10.4 µg/L | 100/100 | SYR4 | 2013–2019 |
| Chloroform | 76.36 µg/L No EPA limit set
worst single sample: 100.2 µg/L | 100/100 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 26.925 µg/L No EPA limit set
worst single sample: 31.4 µg/L | 100/100 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 52.655 µg/L No EPA limit set
worst single sample: 81 µg/L | 98/100 | SYR4 | 2013–2019 |
| Copper | 276.55 µg/L 21% of the EPA limit 1300 µg/L
worst single sample: 298 µg/L | 34/100 | SYR4 | 2013–2019 |
| Lead | 43.5 µg/L 290% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 243 µg/L | 31/100 | SYR4 | 2013–2019 |
| Dibromochloromethane | 1.2 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 22/100 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 3.4 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 16/100 | SYR4 | 2013–2019 |
| Lead | 0.0034 mg/L 23% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Fluoride | 746.2 µg/L 19% of the EPA limit 4000 µg/L
worst single sample: 788 µg/L | 5/8 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 6.97 µg/L No EPA limit set
worst single sample: 7.2 µg/L | 3/100 | SYR4 | 2013–2019 |
| Atrazine | 0.5750 µg/L 19% of the EPA limit 3 µg/L
worst single sample: 0.6000 µg/L | 2/11 | SYR4 | 2014–2019 |
| Nitrate | 1010 µg/L 10% of the EPA limit 10000 µg/L | 2/16 | SYR4 | 2012–2019 |
94 contaminants tested, none detected
Utility contact
Frequently asked questions about King, City of
Is King, City of tap water safe to drink?
EPA monitoring detected 15 contaminants in King, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in King, City of's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does King, City of serve?
King, City of reports serving 23,370 people in North Carolina, per its EPA record.
Has King, City of had any water quality violations?
The EPA has 116 violations on file for King, City of, of which 56 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.