← North Carolina

Tap water quality report

Davidson Water Inc

EPA monitoring tested this supplier for 110 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
17
detected
154,307
people served
0
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Davidson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
54
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
84.465 µg/L 106%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 114.8 µg/L
252/252 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
52.325 µg/L 87%
of the EPA limit 60 µg/L
worst single sample: 79.1 µg/L
252/252 SYR4 2012–2019
Chloroform
65.825 µg/L
No EPA limit set
worst single sample: 96.4 µg/L
240/240 SYR4 2012–2019
Dichloroacetic Acid
30 µg/L
No EPA limit set
worst single sample: 46.8 µg/L
240/240 SYR4 2012–2019
Trichloroacetic Acid
19.205 µg/L
No EPA limit set
worst single sample: 24.3 µg/L
240/240 SYR4 2012–2019
Bromodichloromethane
14.546 µg/L
No EPA limit set
worst single sample: 17 µg/L
239/240 SYR4 2012–2019
Dibromochloromethane
4.3925 µg/L
No EPA limit set
worst single sample: 5.2 µg/L
211/240 SYR4 2012–2019
Chlorite
290 µg/L 29%
of the EPA limit 1000 µg/L
worst single sample: 320 µg/L
75/108 SYR4 2014–2019
Copper
164.5 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 200 µg/L
59/150 SYR4 2013–2019
Dibromoacetic Acid
3 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
59/240 SYR4 2012–2019
Monochloroacetic Acid
5.175 µg/L
No EPA limit set
worst single sample: 6 µg/L
46/240 SYR4 2012–2019
Monobromoacetic Acid
6 µg/L
No EPA limit set
worst single sample: 7 µg/L
35/240 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Fluoride
1002.65 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1070 µg/L
4/8 SYR4 2012–2019
Lead
4 µg/L 27%
of the EPA limit 15 µg/L
3/150 SYR4 2013–2019
Atrazine
0.8950 µg/L 30%
of the EPA limit 3 µg/L
worst single sample: 0.9000 µg/L
2/12 SYR4 2012–2017
Bromoform
1.033 µg/L
No EPA limit set
1/240 SYR4 2012–2019
93 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitrateNitrate-NitriteNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RAY, JONATHAN
Phone
336-731-5537
Email
[email protected]

Frequently asked questions about Davidson Water Inc

Is Davidson Water Inc tap water safe to drink?

EPA monitoring detected 17 contaminants in Davidson Water Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Davidson Water Inc's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Chloroform, Dichloroacetic Acid, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Davidson Water Inc serve?

Davidson Water Inc reports serving 154,307 people in North Carolina, per its EPA record.

Has Davidson Water Inc had any water quality violations?

The EPA has 54 violations on file for Davidson Water Inc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.