← North Carolina

Tap water quality report

Yanceyville, Town of

EPA monitoring tested this supplier for 78 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
11
detected
1,937
people served
145
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Caswell

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

145
health-based violations
371
violations on file
12
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
119.845 µg/L 200%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 134.5 µg/L
78/78 SYR4 2012–2019
TTHM
106.08 µg/L 133%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 123 µg/L
77/77 SYR4 2012–2019
Bromodichloromethane
12 µg/L
No EPA limit set
worst single sample: 13 µg/L
50/50 SYR4 2013–2019
Chloroform
77 µg/L
No EPA limit set
worst single sample: 81.7 µg/L
50/50 SYR4 2013–2019
Dichloroacetic Acid
34.5 µg/L
No EPA limit set
worst single sample: 38.3 µg/L
49/50 SYR4 2013–2019
Trichloroacetic Acid
37.28 µg/L
No EPA limit set
worst single sample: 54 µg/L
49/50 SYR4 2013–2019
Dibromochloromethane
2.8 µg/L
No EPA limit set
worst single sample: 3 µg/L
25/50 SYR4 2013–2019
Monochloroacetic Acid
16.75 µg/L
No EPA limit set
worst single sample: 21 µg/L
18/50 SYR4 2013–2019
Fluoride
480 µg/L 12%
of the EPA limit 4000 µg/L
worst single sample: 490 µg/L
6/8 SYR4 2012–2019
Monobromoacetic Acid
9.4 µg/L
No EPA limit set
worst single sample: 10 µg/L
5/50 SYR4 2013–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
3/3 LCR 2026
67 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNitrateNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NICHOLS, ROBERT
Phone
334-345-0158
Email
[email protected]

Frequently asked questions about Yanceyville, Town of

Is Yanceyville, Town of tap water safe to drink?

EPA monitoring detected 11 contaminants in Yanceyville, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Yanceyville, Town of's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), TTHM, Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Yanceyville, Town of serve?

Yanceyville, Town of reports serving 1,937 people in North Carolina, per its EPA record.

Has Yanceyville, Town of had any water quality violations?

The EPA has 371 violations on file for Yanceyville, Town of, of which 145 are health-based (a contaminant limit or required treatment was breached) and 12 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.