← North Carolina

Tap water quality report

Forest Cove-Sect Ii

EPA monitoring tested this supplier for 78 contaminants and detected 6. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
6
detected
83
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Gaston

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
13
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1994-01-01
TT Health-based Resolved 1994-01-01
TT Health-based Resolved 1994-01-01
TT Health-based Resolved 1994-01-01
Other Monitoring Resolved 2025-07-01
MR Monitoring Resolved 2023-10-01
MR Monitoring Resolved 2023-10-01
MR Monitoring Resolved 2023-10-01
MR Monitoring Resolved 2023-10-01
MR Monitoring Resolved 2023-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2200 µg/L 22%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
382.65 µg/L 29%
of the EPA limit 1300 µg/L
worst single sample: 483 µg/L
10/10 SYR4 2014–2017
Lead
0.0230 mg/L 153%
above the EPA limit of 0.0150 mg/L
2/2 LCR 1993
Fluoride
130 µg/L 3.3%
of the EPA limit 4000 µg/L
1/3 SYR4 2013–2019
Lead
3 µg/L 20%
of the EPA limit 15 µg/L
1/10 SYR4 2014–2017
Nitrate-Nitrite
1900 µg/L 19%
of the EPA limit 10000 µg/L
1/1 SYR4 2015
72 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLIRON, BRENT
Phone
919-653-6999
Email
[email protected]

Frequently asked questions about Forest Cove-Sect Ii

Is Forest Cove-Sect Ii tap water safe to drink?

EPA monitoring detected 6 contaminants in Forest Cove-Sect Ii's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Forest Cove-Sect Ii's water?

EPA monitoring detected Nitrate, Copper, Lead, Fluoride, Lead, and others. The full list with the level and data source for each is above.

How many people does Forest Cove-Sect Ii serve?

Forest Cove-Sect Ii reports serving 83 people in North Carolina, per its EPA record.

Has Forest Cove-Sect Ii had any water quality violations?

The EPA has 13 violations on file for Forest Cove-Sect Ii, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.