← Missouri

Tap water quality report

Taneycomo Highlands Subd Inc

EPA monitoring tested this supplier for 69 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
9
detected
85
people served
17
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Taney

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

17
health-based violations
62
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MCL Health-based Resolved 2002-09-01 → 2002-09-30
MCL Health-based Resolved 2002-09-01 → 2002-09-30
MCL Health-based Resolved 2002-09-01 → 2002-09-30
MCL Health-based Resolved 2002-09-01 → 2002-09-30
MCL Health-based Resolved 2001-11-01 → 2001-11-30
MCL Health-based Resolved 2001-11-01 → 2001-11-30
MCL Health-based Resolved 2001-11-01 → 2001-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.00090 mg/L 6%
of the EPA limit 0.0150 mg/L
26/26 LCR 2024
Copper
21.345 µg/L 1.6%
of the EPA limit 1300 µg/L
worst single sample: 33.5 µg/L
18/18 SYR4 2012–2019
Barium
9.987 µg/L 0.5%
of the EPA limit 2000 µg/L
worst single sample: 10 µg/L
3/3 SYR4 2013–2019
Chloroform
0.7200 µg/L
No EPA limit set
worst single sample: 0.7300 µg/L
3/6 SYR4 2013–2019
Lead
1.218 µg/L 8.1%
of the EPA limit 15 µg/L
worst single sample: 1.22 µg/L
3/18 SYR4 2012–2019
Chromium
4.537 µg/L 4.5%
of the EPA limit 100 µg/L
worst single sample: 4.62 µg/L
2/3 SYR4 2013–2019
Nitrate-Nitrite
11 µg/L 0.1%
of the EPA limit 10000 µg/L
2/16 SYR4 2012–2019
Bromodichloromethane
0.5300 µg/L
No EPA limit set
1/6 SYR4 2013–2019
Dibromochloromethane
0.6400 µg/L
No EPA limit set
1/6 SYR4 2013–2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GURNEY, JUDITH
Phone
417-251-1216
Email
[email protected]

Frequently asked questions about Taneycomo Highlands Subd Inc

Is Taneycomo Highlands Subd Inc tap water safe to drink?

EPA monitoring detected 9 contaminants in Taneycomo Highlands Subd Inc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Taneycomo Highlands Subd Inc's water?

EPA monitoring detected Lead, Copper, Barium, Chloroform, Lead, and others. The full list with the level and data source for each is above.

How many people does Taneycomo Highlands Subd Inc serve?

Taneycomo Highlands Subd Inc reports serving 85 people in Missouri, per its EPA record.

Has Taneycomo Highlands Subd Inc had any water quality violations?

The EPA has 62 violations on file for Taneycomo Highlands Subd Inc, of which 17 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.