| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 1996-02-01 → 1996-02-29 |
| TT | Health-based | Resolved | 1996-02-01 → 1996-02-29 |
| MCL | Health-based | Archived | 1992-02-01 → 1992-02-29 |
| MCL | Health-based | Archived | 1992-02-01 → 1992-02-29 |
| MCL | Health-based | Archived | 1992-02-01 → 1992-02-29 |
| RPT | Monitoring | Unaddressed | 2025-07-02 |
| Other | Monitoring | Resolved | 2022-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 9.904 µg/L No EPA limit set
worst single sample: 11.4 µg/L | 135/143 | SYR4 | 2012–2019 |
| Chloroform | 49.86 µg/L No EPA limit set
worst single sample: 80 µg/L | 135/143 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.7145 µg/L No EPA limit set
worst single sample: 3.2 µg/L | 132/143 | SYR4 | 2012–2019 |
| TTHM | 62.625 µg/L 78% of the EPA limit 80 µg/L
worst single sample: 92.9 µg/L | 116/116 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 22.845 µg/L No EPA limit set
worst single sample: 35.7 µg/L | 114/114 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 45.64 µg/L 76% of the EPA limit 60 µg/L
worst single sample: 80.9 µg/L | 114/114 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 18.015 µg/L No EPA limit set
worst single sample: 57.6 µg/L | 114/114 | SYR4 | 2012–2019 |
| Copper | 203 µg/L 16% of the EPA limit 1300 µg/L
worst single sample: 1980 µg/L | 106/106 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 710 µg/L 7.1% of the EPA limit 10000 µg/L
worst single sample: 770 µg/L | 104/124 | SYR4 | 2012–2019 |
| Lead | 7.552 µg/L 50% of the EPA limit 15 µg/L
worst single sample: 33.6 µg/L | 62/106 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 7.1645 µg/L No EPA limit set
worst single sample: 9.38 µg/L | 30/114 | SYR4 | 2012–2019 |
| Barium | 33.575 µg/L 1.7% of the EPA limit 2000 µg/L
worst single sample: 33.9 µg/L | 26/26 | SYR4 | 2012–2019 |
| Fluoride | 934 µg/L 23% of the EPA limit 4000 µg/L
worst single sample: 1010 µg/L | 25/26 | SYR4 | 2012–2019 |
| Lead | 0.0029 mg/L 19% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2024 |
| Chromium | 2.986 µg/L 3% of the EPA limit 100 µg/L
worst single sample: 3.21 µg/L | 9/26 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 2.48 pCi/L 50% of the EPA limit 5 pCi/L
worst single sample: 2.9 pCi/L | 8/8 | SYR4 | 2012–2018 |
| Xylenes, Total | 2.845 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 3.22 µg/L | 4/27 | SYR4 | 2012–2019 |
| Ethylbenzene | 0.5300 µg/L 0.1% of the EPA limit 700 µg/L | 1/27 | SYR4 | 2012–2019 |
| Toluene | 1.01 µg/L 0.1% of the EPA limit 1000 µg/L | 1/27 | SYR4 | 2012–2019 |
80 contaminants tested, none detected
Utility contact
Frequently asked questions about Branson
Is Branson tap water safe to drink?
EPA monitoring detected 19 contaminants in Branson's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Branson's water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Branson serve?
Branson reports serving 12,640 people in Missouri, per its EPA record.
Has Branson had any water quality violations?
The EPA has 7 violations on file for Branson, of which 5 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.