← Missouri

Tap water quality report

Farmington Correctional Center

EPA monitoring tested this supplier for 101 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

101
contaminants tested
12
detected
3,500
people served
302
health-based violations
Water source
Ground water
Ownership
State government
Counties served
St. Francois

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

302
health-based violations
382
violations on file
3
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-04-01 → 2024-06-30
MCL Health-based Resolved 2024-04-01 → 2024-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
123.6 µg/L 9.5%
of the EPA limit 1300 µg/L
worst single sample: 1520 µg/L
62/66 SYR4 2012–2018
Nitrate-Nitrite
634.5 µg/L 6.3%
of the EPA limit 10000 µg/L
worst single sample: 1070 µg/L
34/34 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
16.3 pCi/L 109%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 29.6 pCi/L
33/34 SYR4 2012–2015
Lead
42.5 µg/L 283%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 53.6 µg/L
26/66 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
24/24 LCR 2025
Combined Radium (-226 And -228)
7.94 pCi/L 159%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 14.6 pCi/L
19/42 SYR4 2012–2019
Tetrachloroethylene
1.4925 µg/L 30%
of the EPA limit 5 µg/L
worst single sample: 1.74 µg/L
16/50 SYR4 2012–2019
Combined Uranium
2 µg/L 6.7%
of the EPA limit 30 µg/L
9/34 SYR4 2012–2015
Chromium
7.08 µg/L 7.1%
of the EPA limit 100 µg/L
worst single sample: 7.5 µg/L
4/6 SYR4 2012–2018
Barium
69.99 µg/L 3.5%
of the EPA limit 2000 µg/L
worst single sample: 71.5 µg/L
3/6 SYR4 2012–2018
Xylenes, Total
1.2875 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1.32 µg/L
2/50 SYR4 2012–2019
Chloroform
0.5800 µg/L
No EPA limit set
1/57 SYR4 2012–2019
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTTHMThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
VINSON, JASON
Phone
573-218-7100
Email
[email protected]

Frequently asked questions about Farmington Correctional Center

Is Farmington Correctional Center tap water safe to drink?

EPA monitoring detected 12 contaminants in Farmington Correctional Center's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Farmington Correctional Center's water?

EPA monitoring detected Copper, Nitrate-Nitrite, Gross Alpha, Excl. Radon And U, Lead, Lead, and others. The full list with the level and data source for each is above.

How many people does Farmington Correctional Center serve?

Farmington Correctional Center reports serving 3,500 people in Missouri, per its EPA record.

Has Farmington Correctional Center had any water quality violations?

The EPA has 382 violations on file for Farmington Correctional Center, of which 302 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.