← Missouri

Tap water quality report

Stoddard County Pwsd 6

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
840
people served
4
health-based violations
Water source
GWP
Ownership
Local government
Counties served
Stoddard

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
8
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MCL Health-based Resolved 2003-06-01 → 2003-06-30
MR Monitoring Archived 1994-04-01 → 1994-04-30
MR Monitoring Archived 1994-04-01 → 1994-04-30
MR Monitoring Archived 1994-04-01 → 1994-04-30
MR Monitoring Archived 1993-09-01 → 1993-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
339.45 µg/L 26%
of the EPA limit 1300 µg/L
worst single sample: 397 µg/L
30/30 SYR4 2013–2019
Lead
0.0012 mg/L 7.7%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Lead
3.668 µg/L 24%
of the EPA limit 15 µg/L
worst single sample: 3.77 µg/L
13/30 SYR4 2013–2019
Bromodichloromethane
6.516 µg/L
No EPA limit set
worst single sample: 6.6 µg/L
7/7 SYR4 2014–2019
Chloroform
16.11 µg/L
No EPA limit set
worst single sample: 16.8 µg/L
7/7 SYR4 2014–2019
Dibromochloromethane
2.239 µg/L
No EPA limit set
worst single sample: 2.32 µg/L
7/7 SYR4 2014–2019
Dichloroacetic Acid
11.21 µg/L
No EPA limit set
worst single sample: 11.6 µg/L
7/7 SYR4 2014–2019
TTHM
24.42 µg/L 31%
of the EPA limit 80 µg/L
worst single sample: 25.2 µg/L
7/7 SYR4 2014–2019
Trichloroacetic Acid
6.363 µg/L
No EPA limit set
worst single sample: 7.11 µg/L
7/7 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
17.37 µg/L 29%
of the EPA limit 60 µg/L
worst single sample: 17.4 µg/L
4/7 SYR4 2014–2019
Dibromoacetic Acid
1.5285 µg/L
No EPA limit set
worst single sample: 1.54 µg/L
2/7 SYR4 2014–2019
Bromoform
0.7900 µg/L
No EPA limit set
1/7 SYR4 2014–2019
Monobromoacetic Acid
1.65 µg/L
No EPA limit set
1/7 SYR4 2014–2019
1 contaminants tested, none detected
Monochloroacetic Acid

Utility contact

Contact
BURNER, CLIFFORD
Phone
573-276-4493

Frequently asked questions about Stoddard County Pwsd 6

Is Stoddard County Pwsd 6 tap water safe to drink?

EPA monitoring detected 13 contaminants in Stoddard County Pwsd 6's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Stoddard County Pwsd 6's water?

EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Stoddard County Pwsd 6 serve?

Stoddard County Pwsd 6 reports serving 840 people in Missouri, per its EPA record.

Has Stoddard County Pwsd 6 had any water quality violations?

The EPA has 8 violations on file for Stoddard County Pwsd 6, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.