Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2017-12-01 → 2017-12-31 |
| TT | Health-based | Resolved | 2017-12-01 → 2017-12-31 |
| TT | Health-based | Resolved | 2017-12-01 → 2017-12-31 |
| TT | Health-based | Resolved | 2017-12-01 → 2017-12-31 |
| MCL | Health-based | Resolved | 2013-09-01 → 2013-09-30 |
| MCL | Health-based | Resolved | 2013-09-01 → 2013-09-30 |
| MCL | Health-based | Resolved | 2013-09-01 → 2013-09-30 |
| MCL | Health-based | Resolved | 2013-09-01 → 2013-09-30 |
| MCL | Health-based | Resolved | 2007-08-01 → 2007-08-31 |
| MCL | Health-based | Resolved | 2007-08-01 → 2007-08-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 238.2 µg/L 18% of the EPA limit 1300 µg/L
worst single sample: 385 µg/L | 93/96 | SYR4 | 2012–2019 |
| Bromodichloromethane | 5.944 µg/L No EPA limit set
worst single sample: 12.6 µg/L | 65/65 | SYR4 | 2012–2019 |
| Chloroform | 7.166 µg/L No EPA limit set
worst single sample: 18.1 µg/L | 65/65 | SYR4 | 2012–2019 |
| Dibromochloromethane | 4.09 µg/L No EPA limit set
worst single sample: 7.79 µg/L | 65/65 | SYR4 | 2012–2019 |
| Lead | 0.0011 mg/L 7.5% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2025 |
| Tetrachloroethylene | 4.429 µg/L 89% of the EPA limit 5 µg/L
worst single sample: 4.6 µg/L | 20/97 | SYR4 | 2012–2019 |
| Lead | 10.0265 µg/L 67% of the EPA limit 15 µg/L
worst single sample: 22.7 µg/L | 18/96 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 8.867 µg/L No EPA limit set
worst single sample: 9.27 µg/L | 14/14 | SYR4 | 2012–2019 |
| TTHM | 29.265 µg/L 37% of the EPA limit 80 µg/L
worst single sample: 39.6 µg/L | 14/14 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 4.3945 µg/L No EPA limit set
worst single sample: 4.51 µg/L | 12/14 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 20 µg/L 0.2% of the EPA limit 10000 µg/L | 10/32 | SYR4 | 2012–2019 |
| Bromoform | 1.052 µg/L No EPA limit set
worst single sample: 1.1 µg/L | 7/65 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 2.885 µg/L No EPA limit set
worst single sample: 2.9 µg/L | 7/14 | SYR4 | 2012–2019 |
| cis-1,2-Dichloroethylene | 0.9340 µg/L 1.3% of the EPA limit 70 µg/L
worst single sample: 0.9400 µg/L | 7/96 | SYR4 | 2012–2019 |
| Barium | 471.5 µg/L 24% of the EPA limit 2000 µg/L
worst single sample: 477 µg/L | 6/6 | SYR4 | 2012–2018 |
| Fluoride | 962.5 µg/L 24% of the EPA limit 4000 µg/L
worst single sample: 970 µg/L | 6/6 | SYR4 | 2012–2018 |
| Trichloroethylene | 0.8700 µg/L 17% of the EPA limit 5 µg/L | 6/97 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 6.8455 µg/L No EPA limit set
worst single sample: 6.85 µg/L | 4/14 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 16.54 µg/L 28% of the EPA limit 60 µg/L
worst single sample: 16.6 µg/L | 4/14 | SYR4 | 2012–2019 |
| Dichloromethane | 2.008 µg/L 40% of the EPA limit 5 µg/L
worst single sample: 2.11 µg/L | 3/97 | SYR4 | 2012–2019 |
| Arsenic | 1.3075 µg/L 13% of the EPA limit 10 µg/L
worst single sample: 1.32 µg/L | 2/6 | SYR4 | 2012–2018 |
| Xylenes, Total | 3.309 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 3.44 µg/L | 2/97 | SYR4 | 2012–2019 |
| Chromium | 1.48 µg/L 1.5% of the EPA limit 100 µg/L | 1/12 | SYR4 | 2012–2018 |
74 contaminants tested, none detected
Utility contact
Frequently asked questions about Sikeston
Is Sikeston tap water safe to drink?
EPA monitoring detected 25 contaminants in Sikeston's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Sikeston's water?
EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.
How many people does Sikeston serve?
Sikeston reports serving 16,291 people in Missouri, per its EPA record.
Has Sikeston had any water quality violations?
The EPA has 21 violations on file for Sikeston, of which 15 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.