← Missouri

Tap water quality report

Perryville

EPA monitoring tested this supplier for 101 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

101
contaminants tested
23
detected
8,555
people served
21
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Perry

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

21
health-based violations
62
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31
TT Health-based Resolved 1999-12-01 → 1999-12-31
TT Health-based Resolved 1999-12-01 → 1999-12-31
TT Health-based Resolved 1999-12-01 → 1999-12-31
TT Health-based Resolved 1995-05-01 → 1995-05-31
TT Health-based Resolved 1995-05-01 → 1995-05-31
TT Health-based Resolved 1995-05-01 → 1995-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
14.7 µg/L
No EPA limit set
worst single sample: 16.2 µg/L
92/121 SYR4 2012–2019
Chloroform
64.41 µg/L
No EPA limit set
worst single sample: 117 µg/L
92/121 SYR4 2012–2019
Dibromochloromethane
4.348 µg/L
No EPA limit set
worst single sample: 6.18 µg/L
85/121 SYR4 2012–2019
TTHM
81.415 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 132 µg/L
78/78 SYR4 2012–2019
Trichloroacetic Acid
26.5 µg/L
No EPA limit set
worst single sample: 35.7 µg/L
78/78 SYR4 2012–2019
Copper
140.4 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 192 µg/L
74/84 SYR4 2012–2019
Dichloroacetic Acid
26.04 µg/L
No EPA limit set
worst single sample: 35.7 µg/L
74/78 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.125 µg/L 89%
of the EPA limit 60 µg/L
worst single sample: 62.2 µg/L
70/78 SYR4 2012–2019
Nitrate-Nitrite
382 µg/L 3.8%
of the EPA limit 10000 µg/L
worst single sample: 1260 µg/L
64/88 SYR4 2012–2019
Barium
147.1 µg/L 7.4%
of the EPA limit 2000 µg/L
worst single sample: 163 µg/L
44/44 SYR4 2012–2019
Fluoride
1274 µg/L 32%
of the EPA limit 4000 µg/L
worst single sample: 1680 µg/L
43/44 SYR4 2012–2019
Lead
2.952 µg/L 20%
of the EPA limit 15 µg/L
worst single sample: 3 µg/L
25/84 SYR4 2012–2019
Lead
0.0021 mg/L 14%
of the EPA limit 0.0150 mg/L
21/21 LCR 2023
Monobromoacetic Acid
6.18 µg/L
No EPA limit set
worst single sample: 6.82 µg/L
21/78 SYR4 2012–2019
Chromium
5.438 µg/L 5.4%
of the EPA limit 100 µg/L
worst single sample: 5.95 µg/L
17/44 SYR4 2012–2019
Arsenic
2.4045 µg/L 24%
of the EPA limit 10 µg/L
worst single sample: 3.21 µg/L
10/44 SYR4 2012–2019
Combined Radium (-226 And -228)
5.05 pCi/L 101%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 5.5 pCi/L
10/11 SYR4 2012–2018
Dibromoacetic Acid
9.4555 µg/L
No EPA limit set
worst single sample: 10.9 µg/L
4/78 SYR4 2012–2019
Lithium
32 µg/L
No EPA limit set
4/12 UCMR-5 2024
Gross Alpha, Excl. Radon And U
18.8 pCi/L 125%
of the EPA limit, at the 95th percentile of samples — 15 pCi/L
worst single sample: 18.9 pCi/L
3/3 SYR4 2014–2015
Bromoform
1.111 µg/L
No EPA limit set
worst single sample: 1.14 µg/L
2/121 SYR4 2012–2019
Atrazine
0.5400 µg/L 18%
of the EPA limit 3 µg/L
1/18 SYR4 2012–2019
P-Dichlorobenzene
0.9300 µg/L 1.2%
of the EPA limit 75 µg/L
1/43 SYR4 2012–2019
78 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RELLERGERT, LYDIA
Phone
573-547-2594
Email
[email protected]

Frequently asked questions about Perryville

Is Perryville tap water safe to drink?

EPA monitoring detected 23 contaminants in Perryville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Perryville's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Trichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Perryville serve?

Perryville reports serving 8,555 people in Missouri, per its EPA record.

Has Perryville had any water quality violations?

The EPA has 62 violations on file for Perryville, of which 21 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.