Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2014-10-01 → 2014-10-31 |
| MCL | Health-based | Resolved | 2014-10-01 → 2014-10-31 |
| MCL | Health-based | Resolved | 2014-10-01 → 2014-10-31 |
| MCL | Health-based | Resolved | 2014-10-01 → 2014-10-31 |
| MCL | Health-based | Resolved | 2011-08-01 → 2011-08-31 |
| MCL | Health-based | Resolved | 2011-08-01 → 2011-08-31 |
| MCL | Health-based | Resolved | 2011-08-01 → 2011-08-31 |
| MCL | Health-based | Resolved | 2011-08-01 → 2011-08-31 |
| MCL | Health-based | Resolved | 2011-08-01 → 2011-08-31 |
| MCL | Health-based | Resolved | 2010-12-01 → 2010-12-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 119.2 µg/L 9.2% of the EPA limit 1300 µg/L
worst single sample: 216 µg/L | 45/51 | SYR4 | 2012–2018 |
| Lead | 0.0011 mg/L 7.2% of the EPA limit 0.0150 mg/L | 26/26 | LCR | 2025 |
| Barium | 377 µg/L 19% of the EPA limit 2000 µg/L
worst single sample: 463 µg/L | 11/11 | SYR4 | 2012–2018 |
| Lead | 3.3005 µg/L 22% of the EPA limit 15 µg/L
worst single sample: 3.57 µg/L | 8/51 | SYR4 | 2012–2018 |
| Arsenic | 3.1245 µg/L 31% of the EPA limit 10 µg/L
worst single sample: 3.24 µg/L | 4/11 | SYR4 | 2012–2018 |
| Chromium | 2.5935 µg/L 2.6% of the EPA limit 100 µg/L
worst single sample: 2.79 µg/L | 4/11 | SYR4 | 2012–2018 |
| Fluoride | 130 µg/L 3.3% of the EPA limit 4000 µg/L | 4/11 | SYR4 | 2012–2018 |
| Gross Alpha, Excl. Radon And U | 6.12 pCi/L 41% of the EPA limit 15 pCi/L
worst single sample: 6.3 pCi/L | 4/5 | SYR4 | 2013–2014 |
| Combined Radium (-226 And -228) | 2.09 pCi/L 42% of the EPA limit 5 pCi/L
worst single sample: 2.2 pCi/L | 3/11 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 12 µg/L 0.1% of the EPA limit 10000 µg/L | 2/60 | SYR4 | 2012–2019 |
| Toluene | 3.9 µg/L 0.4% of the EPA limit 1000 µg/L | 1/11 | SYR4 | 2012–2018 |
77 contaminants tested, none detected
Utility contact
Frequently asked questions about St James
Is St James tap water safe to drink?
EPA monitoring detected 18 contaminants in St James's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in St James's water?
EPA monitoring detected Copper, Lead, Barium, Lead, Arsenic, and others. The full list with the level and data source for each is above.
How many people does St James serve?
St James reports serving 3,935 people in Missouri, per its EPA record.
Has St James had any water quality violations?
The EPA has 31 violations on file for St James, of which 21 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.