Tap water quality report

Pike County Pwsd 1

EPA monitoring tested this supplier for 44 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
16
detected
7,590
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Pike

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
10
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2007-09-01 → 2007-09-30
MR Monitoring Resolved 2007-09-01 → 2007-09-30
MR Monitoring Resolved 2007-09-01 → 2007-09-30
MR Monitoring Resolved 2004-07-01 → 2004-07-31
MR Monitoring Resolved 2004-07-01 → 2004-07-31
MR Monitoring Resolved 2004-07-01 → 2004-07-31
MR Monitoring Resolved 1997-01-01 → 1997-01-31
MR Monitoring Resolved 1997-01-01 → 1997-01-31
MR Monitoring Resolved 1997-01-01 → 1997-01-31
MR Monitoring Resolved 1997-01-01 → 1997-01-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0110 µg/L 7/8 2024
PFBS 0.0039 µg/L 2/8 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
753.4 µg/L 58%
of the EPA limit 1300 µg/L
worst single sample: 1220 µg/L
59/60 SYR4 2013–2019
Bromodichloromethane
12.855 µg/L
No EPA limit set
worst single sample: 15 µg/L
50/50 SYR4 2013–2019
Chloroform
60.69 µg/L
No EPA limit set
worst single sample: 66.1 µg/L
50/50 SYR4 2013–2019
Dichloroacetic Acid
29.41 µg/L
No EPA limit set
worst single sample: 33.2 µg/L
50/50 SYR4 2013–2019
TTHM
68.37 µg/L 85%
of the EPA limit 80 µg/L
worst single sample: 78.8 µg/L
50/50 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
50.575 µg/L 84%
of the EPA limit 60 µg/L
worst single sample: 55.5 µg/L
50/50 SYR4 2013–2019
Trichloroacetic Acid
18.02 µg/L
No EPA limit set
worst single sample: 26.2 µg/L
49/50 SYR4 2013–2019
Dibromochloromethane
2.716 µg/L
No EPA limit set
worst single sample: 3.51 µg/L
45/50 SYR4 2013–2019
Lead
8.4595 µg/L 56%
of the EPA limit 15 µg/L
worst single sample: 11.8 µg/L
44/60 SYR4 2013–2019
Lead
0.0018 mg/L 12%
of the EPA limit 0.0150 mg/L
23/23 LCR 2025
Monobromoacetic Acid
11.15 µg/L
No EPA limit set
worst single sample: 11.7 µg/L
12/50 SYR4 2013–2019
Dibromoacetic Acid
1.0495 µg/L
No EPA limit set
worst single sample: 1.05 µg/L
2/50 SYR4 2013–2019
Monochloroacetic Acid
10.415 µg/L
No EPA limit set
worst single sample: 10.5 µg/L
2/50 SYR4 2013–2019
Lithium
16 µg/L
No EPA limit set
1/8 UCMR-5 2024
28 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformHfpo-DaNetfosaaNfdhaNmefosaaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfuna

Utility contact

Contact
LUEBRECHT, JANICE
Phone
573-324-3221
Email
[email protected]

Frequently asked questions about Pike County Pwsd 1

Is Pike County Pwsd 1 tap water safe to drink?

EPA monitoring detected 16 contaminants in Pike County Pwsd 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pike County Pwsd 1's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Pike County Pwsd 1 serve?

Pike County Pwsd 1 reports serving 7,590 people in Missouri, per its EPA record.

Has Pike County Pwsd 1 had any water quality violations?

The EPA has 10 violations on file for Pike County Pwsd 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.