← Missouri

Tap water quality report

Livingston County Pwsd 2

EPA monitoring tested this supplier for 68 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
16
detected
2,215
people served
10
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Livingston

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

10
health-based violations
27
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-01-13
TT Health-based Resolved 2024-01-13
TT Health-based Resolved 2024-01-13
TT Health-based Resolved 2024-01-13
TT Health-based Resolved 2024-01-13
TT Health-based Resolved 2024-01-13
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31
MCL Health-based Resolved 2011-08-01 → 2011-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
96.7 µg/L 7.4%
of the EPA limit 1300 µg/L
worst single sample: 144 µg/L
31/32 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
24/24 LCR 2024
Nitrate-Nitrite
250 µg/L 2.5%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
21.7 µg/L
No EPA limit set
worst single sample: 26.9 µg/L
9/9 SYR4 2013–2019
Bromoform
9.556 µg/L
No EPA limit set
worst single sample: 9.82 µg/L
9/9 SYR4 2013–2019
Chloroform
18.916 µg/L
No EPA limit set
worst single sample: 25.9 µg/L
9/9 SYR4 2013–2019
Dibromochloromethane
19.48 µg/L
No EPA limit set
worst single sample: 21.2 µg/L
9/9 SYR4 2013–2019
Lead
9.8215 µg/L 65%
of the EPA limit 15 µg/L
worst single sample: 13.5 µg/L
8/31 SYR4 2012–2018
Dibromoacetic Acid
4.309 µg/L
No EPA limit set
worst single sample: 4.54 µg/L
7/7 SYR4 2013–2019
TTHM
70.31 µg/L 88%
of the EPA limit 80 µg/L
worst single sample: 79.7 µg/L
7/7 SYR4 2013–2019
Dichloroacetic Acid
8.33 µg/L
No EPA limit set
worst single sample: 8.77 µg/L
3/7 SYR4 2013–2019
Barium
20.4 µg/L 1%
of the EPA limit 2000 µg/L
2/2 SYR4 2014–2017
Chromium
4.7735 µg/L 4.8%
of the EPA limit 100 µg/L
worst single sample: 4.89 µg/L
2/2 SYR4 2014–2017
Fluoride
129.5 µg/L 3.2%
of the EPA limit 4000 µg/L
worst single sample: 130 µg/L
2/2 SYR4 2014–2017
Total Haloacetic Acids (HAA5)
15.135 µg/L 25%
of the EPA limit 60 µg/L
worst single sample: 15.8 µg/L
2/7 SYR4 2013–2019
Trichloroacetic Acid
2.44 µg/L
No EPA limit set
worst single sample: 2.51 µg/L
2/7 SYR4 2013–2019
52 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BECK, DAVID
Phone
660-646-4083

Frequently asked questions about Livingston County Pwsd 2

Is Livingston County Pwsd 2 tap water safe to drink?

EPA monitoring detected 16 contaminants in Livingston County Pwsd 2's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Livingston County Pwsd 2's water?

EPA monitoring detected Copper, Lead, Nitrate-Nitrite, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Livingston County Pwsd 2 serve?

Livingston County Pwsd 2 reports serving 2,215 people in Missouri, per its EPA record.

Has Livingston County Pwsd 2 had any water quality violations?

The EPA has 27 violations on file for Livingston County Pwsd 2, of which 10 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.