Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2001-03-01 → 2001-03-31 |
| TT | Health-based | Resolved | 2001-03-01 → 2001-03-31 |
| TT | Health-based | Resolved | 2001-03-01 → 2001-03-31 |
| TT | Health-based | Resolved | 2001-03-01 → 2001-03-31 |
| TT | Health-based | Resolved | 1998-04-01 → 1998-04-30 |
| TT | Health-based | Resolved | 1998-04-01 → 1998-04-30 |
| TT | Health-based | Resolved | 1998-04-01 → 1998-04-30 |
| TT | Health-based | Resolved | 1998-01-01 → 1998-01-31 |
| TT | Health-based | Resolved | 1998-01-01 → 1998-01-31 |
| TT | Health-based | Resolved | 1998-01-01 → 1998-01-31 |
PFAS detected
| Contaminant | Max | Detection rate | Period |
|---|---|---|---|
| Pfba | 0.0071 µg/L | 3/4 | 2024 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chlorite | 480 µg/L 48% of the EPA limit 1000 µg/L
worst single sample: 590 µg/L | 289/289 | SYR4 | 2012–2019 |
| Copper | 134.95 µg/L 10% of the EPA limit 1300 µg/L
worst single sample: 226 µg/L | 68/68 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.31 µg/L No EPA limit set
worst single sample: 10.8 µg/L | 60/60 | SYR4 | 2012–2019 |
| Chloroform | 51.645 µg/L No EPA limit set
worst single sample: 53.1 µg/L | 60/60 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.391 µg/L No EPA limit set
worst single sample: 2.85 µg/L | 60/60 | SYR4 | 2012–2019 |
| TTHM | 61.845 µg/L 77% of the EPA limit 80 µg/L
worst single sample: 64 µg/L | 52/52 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 9.907 µg/L No EPA limit set
worst single sample: 10.8 µg/L | 52/52 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 20.7 µg/L No EPA limit set
worst single sample: 26.8 µg/L | 51/52 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 30.175 µg/L 50% of the EPA limit 60 µg/L
worst single sample: 36.7 µg/L | 50/52 | SYR4 | 2012–2019 |
| Lead | 0.0022 mg/L 15% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2025 |
| Lead | 6.969 µg/L 46% of the EPA limit 15 µg/L
worst single sample: 8.04 µg/L | 19/67 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 1020 µg/L 10% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Barium | 60.975 µg/L 3% of the EPA limit 2000 µg/L
worst single sample: 61.5 µg/L | 8/8 | SYR4 | 2012–2019 |
| Fluoride | 878 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 920 µg/L | 8/8 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 7.9075 µg/L No EPA limit set
worst single sample: 7.98 µg/L | 6/52 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 10.2855 µg/L No EPA limit set
worst single sample: 10.6 µg/L | 2/52 | SYR4 | 2012–2019 |
| Atrazine | 0.7600 µg/L 25% of the EPA limit 3 µg/L | 1/32 | SYR4 | 2012–2019 |
| Chromium | 1.04 µg/L 1% of the EPA limit 100 µg/L | 1/8 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 8.76 µg/L No EPA limit set | 1/52 | SYR4 | 2012–2019 |
| Xylenes, Total | 0.6400 µg/L 0% of the EPA limit 10000 µg/L | 1/8 | SYR4 | 2012–2019 |
78 contaminants tested, none detected
Utility contact
Frequently asked questions about Macon
Is Macon tap water safe to drink?
EPA monitoring detected 21 contaminants in Macon's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Macon's water?
EPA monitoring detected Chlorite, Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Macon serve?
Macon reports serving 5,489 people in Missouri, per its EPA record.
Has Macon had any water quality violations?
The EPA has 50 violations on file for Macon, of which 23 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.