← Missouri

Tap water quality report

Lexington

EPA monitoring tested this supplier for 98 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
22
detected
4,729
people served
80
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Lafayette

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

80
health-based violations
106
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-06-01 → 2019-06-30
TT Health-based Resolved 2019-06-01 → 2019-06-30
TT Health-based Resolved 2019-06-01 → 2019-06-30
TT Health-based Resolved 2019-06-01 → 2019-06-30
TT Health-based Resolved 2019-03-01 → 2019-03-31
TT Health-based Resolved 2019-03-01 → 2019-03-31
TT Health-based Resolved 2019-03-01 → 2019-03-31
TT Health-based Resolved 2019-03-01 → 2019-03-31
TT Health-based Resolved 2017-12-01
TT Health-based Resolved 2017-12-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
23.4 µg/L
No EPA limit set
worst single sample: 28.6 µg/L
86/86 SYR4 2012–2019
Chloroform
49.8 µg/L
No EPA limit set
worst single sample: 60.6 µg/L
86/86 SYR4 2012–2019
TTHM
75.595 µg/L 94%
of the EPA limit 80 µg/L
worst single sample: 87.1 µg/L
78/78 SYR4 2012–2019
Trichloroacetic Acid
20.42 µg/L
No EPA limit set
worst single sample: 28.1 µg/L
77/77 SYR4 2012–2019
Dichloroacetic Acid
37.5 µg/L
No EPA limit set
worst single sample: 50.3 µg/L
76/77 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
63.16 µg/L 105%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 97.5 µg/L
73/77 SYR4 2012–2019
Dibromochloromethane
15.99 µg/L
No EPA limit set
worst single sample: 16.7 µg/L
68/86 SYR4 2012–2019
Copper
593.9 µg/L 46%
of the EPA limit 1300 µg/L
worst single sample: 1620 µg/L
67/68 SYR4 2012–2019
Dibromoacetic Acid
7.559 µg/L
No EPA limit set
worst single sample: 8.69 µg/L
47/77 SYR4 2012–2019
Bromoform
3.17 µg/L
No EPA limit set
worst single sample: 3.63 µg/L
25/86 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
24/24 LCR 2024
Lead
8.613 µg/L 57%
of the EPA limit 15 µg/L
worst single sample: 24.5 µg/L
24/68 SYR4 2012–2019
Monobromoacetic Acid
12.3 µg/L
No EPA limit set
worst single sample: 12.7 µg/L
21/77 SYR4 2012–2019
Atrazine
3.468 µg/L 116%
of the EPA limit, at the 95th percentile of samples — 3 µg/L
worst single sample: 3.82 µg/L
17/33 SYR4 2012–2019
Nitrate-Nitrite
3210 µg/L 32%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Barium
61.87 µg/L 3.1%
of the EPA limit 2000 µg/L
worst single sample: 64.6 µg/L
8/8 SYR4 2012–2019
Fluoride
435.5 µg/L 11%
of the EPA limit 4000 µg/L
worst single sample: 460 µg/L
8/8 SYR4 2012–2019
Chromium
2.595 µg/L 2.6%
of the EPA limit 100 µg/L
worst single sample: 2.67 µg/L
4/8 SYR4 2012–2019
Monochloroacetic Acid
33.22 µg/L
No EPA limit set
worst single sample: 35.6 µg/L
3/77 SYR4 2012–2019
Lithium
22.4 µg/L
No EPA limit set
2/2 UCMR-5 2025
Arsenic
2.44 µg/L 24%
of the EPA limit 10 µg/L
1/8 SYR4 2012–2019
Mercury
0.6800 µg/L 34%
of the EPA limit 2 µg/L
1/8 SYR4 2012–2019
76 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DIRECTOR, PUBLIC WORKS
Phone
660-232-2684
Email
[email protected]

Frequently asked questions about Lexington

Is Lexington tap water safe to drink?

EPA monitoring detected 22 contaminants in Lexington's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lexington's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Trichloroacetic Acid, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Lexington serve?

Lexington reports serving 4,729 people in Missouri, per its EPA record.

Has Lexington had any water quality violations?

The EPA has 106 violations on file for Lexington, of which 80 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.