← Missouri

Tap water quality report

Holden

EPA monitoring tested this supplier for 69 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
20
detected
2,683
people served
26
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Johnson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

26
health-based violations
44
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2016-04-01 → 2016-06-30
MCL Health-based Resolved 2016-04-01 → 2016-06-30
MCL Health-based Resolved 2016-04-01 → 2016-06-30
MCL Health-based Resolved 2016-04-01 → 2016-06-30
TT Health-based Resolved 2007-07-01 → 2007-07-31
TT Health-based Resolved 2007-07-01 → 2007-07-31
TT Health-based Resolved 2007-07-01 → 2007-07-31
TT Health-based Resolved 2007-07-01 → 2007-07-31
TT Health-based Resolved 2007-05-01 → 2007-05-31
TT Health-based Resolved 2007-05-01 → 2007-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chlorite
440 µg/L 44%
of the EPA limit 1000 µg/L
worst single sample: 1160 µg/L
289/291 SYR4 2012–2019
Bromodichloromethane
19.26 µg/L
No EPA limit set
worst single sample: 21.4 µg/L
89/89 SYR4 2012–2019
Chloroform
72.54 µg/L
No EPA limit set
worst single sample: 92.3 µg/L
89/89 SYR4 2012–2019
Dibromochloromethane
7.414 µg/L
No EPA limit set
worst single sample: 10.8 µg/L
89/89 SYR4 2012–2019
TTHM
98.3 µg/L 123%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 112 µg/L
81/81 SYR4 2012–2019
Trichloroacetic Acid
15.35 µg/L
No EPA limit set
worst single sample: 24.1 µg/L
79/79 SYR4 2012–2019
Dichloroacetic Acid
24.34 µg/L
No EPA limit set
worst single sample: 30.4 µg/L
78/79 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
41.89 µg/L 70%
of the EPA limit 60 µg/L
worst single sample: 52.7 µg/L
75/79 SYR4 2012–2019
Dibromoacetic Acid
3.726 µg/L
No EPA limit set
worst single sample: 4.32 µg/L
55/79 SYR4 2012–2019
Copper
41.42 µg/L 3.2%
of the EPA limit 1300 µg/L
worst single sample: 44.5 µg/L
38/38 SYR4 2012–2019
Atrazine
0.8900 µg/L 30%
of the EPA limit 3 µg/L
worst single sample: 1.25 µg/L
26/31 SYR4 2012–2019
Bromoform
1.0425 µg/L
No EPA limit set
worst single sample: 1.18 µg/L
26/89 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Monobromoacetic Acid
13.52 µg/L
No EPA limit set
worst single sample: 14.8 µg/L
17/79 SYR4 2012–2019
Nitrate-Nitrite
480 µg/L 4.8%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
7.0395 µg/L 47%
of the EPA limit 15 µg/L
worst single sample: 11.5 µg/L
12/38 SYR4 2012–2019
Barium
83.36 µg/L 4.2%
of the EPA limit 2000 µg/L
worst single sample: 84.2 µg/L
8/8 SYR4 2012–2019
Fluoride
202.5 µg/L 5.1%
of the EPA limit 4000 µg/L
worst single sample: 210 µg/L
6/8 SYR4 2012–2019
Monochloroacetic Acid
34.375 µg/L
No EPA limit set
worst single sample: 38.2 µg/L
4/79 SYR4 2012–2019
Chromium
2.675 µg/L 2.7%
of the EPA limit 100 µg/L
worst single sample: 2.81 µg/L
3/8 SYR4 2012–2019
49 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HOLDEN BOARD OF PUBLIC WORKS
Phone
816-732-6343

Frequently asked questions about Holden

Is Holden tap water safe to drink?

EPA monitoring detected 20 contaminants in Holden's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Holden's water?

EPA monitoring detected Chlorite, Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Holden serve?

Holden reports serving 2,683 people in Missouri, per its EPA record.

Has Holden had any water quality violations?

The EPA has 44 violations on file for Holden, of which 26 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.