← Missouri

Tap water quality report

Blue Springs

EPA monitoring tested this supplier for 44 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

44
contaminants tested
12
detected
61,084
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Jackson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
6
violations on file
1
still open
ViolationTypeStatusPeriod
RPT Monitoring Unaddressed 2025-07-02
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
MON Monitoring Resolved 2024-08-01 → 2024-08-31
Other Monitoring Resolved 2013-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
36.07 µg/L 2.8%
of the EPA limit 1300 µg/L
worst single sample: 56.3 µg/L
87/90 SYR4 2012–2018
Chloroform
12.59 µg/L
No EPA limit set
worst single sample: 19.4 µg/L
58/58 SYR4 2012–2019
Dichloroacetic Acid
25.345 µg/L
No EPA limit set
worst single sample: 30 µg/L
58/58 SYR4 2012–2019
TTHM
14.2 µg/L 18%
of the EPA limit 80 µg/L
worst single sample: 20.7 µg/L
49/58 SYR4 2012–2019
Bromodichloromethane
1.352 µg/L
No EPA limit set
worst single sample: 1.59 µg/L
37/58 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
29.55 µg/L 49%
of the EPA limit 60 µg/L
worst single sample: 34 µg/L
31/58 SYR4 2012–2019
Trichloroacetic Acid
3.982 µg/L
No EPA limit set
worst single sample: 5.46 µg/L
30/58 SYR4 2012–2019
Lead
6.083 µg/L 41%
of the EPA limit 15 µg/L
worst single sample: 10.1 µg/L
27/90 SYR4 2012–2018
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
24/24 LCR 2024
Lithium
53.6 µg/L
No EPA limit set
8/8 UCMR-5 2024
Monobromoacetic Acid
3.2745 µg/L
No EPA limit set
worst single sample: 3.28 µg/L
2/58 SYR4 2012–2019
Dibromochloromethane
0.5100 µg/L
No EPA limit set
1/58 SYR4 2012–2019
32 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBromoformDibromoacetic AcidHfpo-DaMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfuna

Utility contact

Contact
CATES, CHRISTINE
Phone
816-228-0195
Email
[email protected]

Frequently asked questions about Blue Springs

Is Blue Springs tap water safe to drink?

EPA monitoring detected 12 contaminants in Blue Springs's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Blue Springs's water?

EPA monitoring detected Copper, Chloroform, Dichloroacetic Acid, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Blue Springs serve?

Blue Springs reports serving 61,084 people in Missouri, per its EPA record.

Has Blue Springs had any water quality violations?

The EPA has 6 violations on file for Blue Springs, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.