← Minnesota

Tap water quality report

Bellechester

EPA monitoring tested this supplier for 47 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

47
contaminants tested
9
detected
169
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Goodhue

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
7
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 1999-01-01 → 1999-03-31
MR Monitoring Archived 1999-01-01 → 1999-03-31
MR Monitoring Archived 1999-01-01 → 1999-03-31
MR Monitoring Archived 1999-01-01 → 1999-03-31
MR Monitoring Archived 1993-07-01 → 1993-09-30
MR Monitoring Archived 1993-07-01 → 1993-09-30
MR Monitoring Archived 1993-07-01 → 1993-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
1440 µg/L 36%
of the EPA limit 4000 µg/L
worst single sample: 1500 µg/L
33/33 SYR4 2012–2019
Copper
124.25 µg/L 9.6%
of the EPA limit 1300 µg/L
worst single sample: 131 µg/L
10/10 SYR4 2014–2017
Lead
2.72 µg/L 18%
of the EPA limit 15 µg/L
worst single sample: 2.9 µg/L
5/10 SYR4 2014–2017
Chloroform
0.5800 µg/L
No EPA limit set
worst single sample: 0.6000 µg/L
2/7 SYR4 2012–2018
Lead
0.0080 mg/L 53%
of the EPA limit 0.0150 mg/L
2/2 LCR 2023
Barium
21.9 µg/L 1.1%
of the EPA limit 2000 µg/L
1/2 SYR4 2017
Bromodichloromethane
0.2000 µg/L
No EPA limit set
1/7 SYR4 2012–2018
Dichloroacetic Acid
1.9 µg/L
No EPA limit set
1/3 SYR4 2012–2018
Trichloroacetic Acid
1.6 µg/L
No EPA limit set
1/3 SYR4 2012–2018
38 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidDibromochloromethaneEthylene DibromideEthylbenzeneGross Alpha, Excl. Radon And UMercuryMonobromoacetic AcidMonochloroacetic AcidNitrate-NitriteSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Phone
6513802026
Email
[email protected]

Frequently asked questions about Bellechester

Is Bellechester tap water safe to drink?

EPA monitoring detected 9 contaminants in Bellechester's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bellechester's water?

EPA monitoring detected Fluoride, Copper, Lead, Chloroform, Lead, and others. The full list with the level and data source for each is above.

How many people does Bellechester serve?

Bellechester reports serving 169 people in Minnesota, per its EPA record.

Has Bellechester had any water quality violations?

The EPA has 7 violations on file for Bellechester, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.