← Minnesota

Tap water quality report

Fridley Terrace Mobile Home Park

EPA monitoring tested this supplier for 47 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

47
contaminants tested
11
detected
1,300
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Anoka

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
11
violations on file
0
still open
ViolationTypeStatusPeriod
MON Monitoring Resolved 2025-12-01 → 2025-12-31
MON Monitoring Resolved 2025-12-01 → 2025-12-31
MON Monitoring Resolved 2025-12-01 → 2025-12-31
MR Monitoring Archived 2025-10-01 → 2025-12-31
MR Monitoring Archived 2025-10-01 → 2025-12-31
MR Monitoring Archived 1994-01-01 → 1994-03-31
MR Monitoring Archived 1994-01-01 → 1994-03-31
MR Monitoring Archived 1994-01-01 → 1994-03-31
MR Monitoring Archived 1991-10-01 → 1991-12-31
MR Monitoring Archived 1991-10-01 → 1991-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
173.55 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 331 µg/L
30/30 SYR4 2012–2018
Nitrate-Nitrite
80 µg/L 0.8%
of the EPA limit 10000 µg/L
10/16 SYR4 2012–2019
Bromodichloromethane
3.92 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
9/10 SYR4 2012–2019
Chloroform
32.6 µg/L
No EPA limit set
worst single sample: 35 µg/L
9/10 SYR4 2012–2019
Dichloroacetic Acid
6.405 µg/L
No EPA limit set
worst single sample: 7 µg/L
8/9 SYR4 2012–2019
Trichloroacetic Acid
5.07 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
8/9 SYR4 2012–2019
Lead
0.0090 mg/L 60%
of the EPA limit 0.0150 mg/L
6/6 LCR 2024
Lead
3.88 µg/L 26%
of the EPA limit 15 µg/L
worst single sample: 4 µg/L
5/30 SYR4 2012–2018
Dibromochloromethane
0.6950 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
2/10 SYR4 2012–2019
Barium
151 µg/L 7.6%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Gross Alpha, Excl. Radon And U
3.5 pCi/L 23%
of the EPA limit 15 pCi/L
1/1 SYR4 2017
36 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidEthylene DibromideEthylbenzeneFluorideMercuryMonobromoacetic AcidMonochloroacetic AcidSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Phone
5077201035
Email
[email protected]

Frequently asked questions about Fridley Terrace Mobile Home Park

Is Fridley Terrace Mobile Home Park tap water safe to drink?

EPA monitoring detected 11 contaminants in Fridley Terrace Mobile Home Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fridley Terrace Mobile Home Park's water?

EPA monitoring detected Copper, Nitrate-Nitrite, Bromodichloromethane, Chloroform, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Fridley Terrace Mobile Home Park serve?

Fridley Terrace Mobile Home Park reports serving 1,300 people in Minnesota, per its EPA record.

Has Fridley Terrace Mobile Home Park had any water quality violations?

The EPA has 11 violations on file for Fridley Terrace Mobile Home Park, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.