← California

Tap water quality report

Hermon Mhp Llc

EPA monitoring tested this supplier for 53 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

53
contaminants tested
13
detected
43
people served
7
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Penobscot

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
81
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 1999-08-01 → 1999-08-31
MCL Health-based Resolved 1999-08-01 → 1999-08-31
MCL Health-based Resolved 1999-08-01 → 1999-08-31
MON Monitoring Archived 2026-03-01 → 2026-03-31
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
940 µg/L 9.4%
of the EPA limit 10000 µg/L
14/14 SYR4 2012–2018
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Copper
84.45 µg/L 6.5%
of the EPA limit 1300 µg/L
worst single sample: 110 µg/L
8/8 SYR4 2012–2018
Lead
1.474 µg/L 9.8%
of the EPA limit 15 µg/L
worst single sample: 1.6 µg/L
5/8 SYR4 2012–2018
Barium
2.77 µg/L 0.1%
of the EPA limit 2000 µg/L
worst single sample: 2.8 µg/L
3/3 SYR4 2012–2018
Chromium
4.37 µg/L 4.4%
of the EPA limit 100 µg/L
worst single sample: 4.6 µg/L
3/3 SYR4 2012–2018
Nitrate-Nitrite
699 µg/L 7%
of the EPA limit 10000 µg/L
worst single sample: 700 µg/L
3/3 SYR4 2012–2018
TTHM
1.97 µg/L 2.5%
of the EPA limit 80 µg/L
worst single sample: 2 µg/L
3/4 SYR4 2012–2018
Antimony, Total
0.5500 µg/L 9.2%
of the EPA limit 6 µg/L
1/3 SYR4 2012–2018
Arsenic
0.5900 µg/L 5.9%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2018
Combined Uranium
3.6 µg/L 12%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Dibromochloromethane
1.1 µg/L
No EPA limit set
1/4 SYR4 2012–2015
Gross Alpha, Excl. Radon And U
3.77 pCi/L 25%
of the EPA limit 15 pCi/L
1/1 SYR4 2015
40 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneBenzeneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChloroformDichloromethaneDibromoacetic AcidDichloroacetic AcidEthylene DibromideEthylbenzeneFluorideMercuryMonobromoacetic AcidMonochloroacetic AcidNitriteSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BEHLING, MICHAEL
Phone
818-635-5155
Email
[email protected]

Frequently asked questions about Hermon Mhp Llc

Is Hermon Mhp Llc tap water safe to drink?

EPA monitoring detected 13 contaminants in Hermon Mhp Llc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Hermon Mhp Llc's water?

EPA monitoring detected Nitrate, Lead, Copper, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Hermon Mhp Llc serve?

Hermon Mhp Llc reports serving 43 people in California, per its EPA record.

Has Hermon Mhp Llc had any water quality violations?

The EPA has 81 violations on file for Hermon Mhp Llc, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.