← Maryland

Tap water quality report

Reservoir Trailer Park

EPA monitoring tested this supplier for 71 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
12
detected
79
people served
45
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Carroll

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

45
health-based violations
63
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-07-01 → 2018-09-30
MCL Health-based Resolved 2018-07-01 → 2018-09-30
MCL Health-based Resolved 2018-07-01 → 2018-09-30
MCL Health-based Resolved 2011-06-01 → 2011-06-30
MCL Health-based Resolved 2011-06-01 → 2011-06-30
MCL Health-based Resolved 2011-06-01 → 2011-06-30
MCL Health-based Resolved 2011-06-01 → 2011-06-30
MCL Health-based Resolved 2010-09-01 → 2010-09-30
MCL Health-based Resolved 2010-09-01 → 2010-09-30
MCL Health-based Resolved 2010-09-01 → 2010-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
12476.5 µg/L 125%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 18200 µg/L
72/72 SYR4 2012–2019
Lead
0.0070 mg/L 47%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Barium
22.7 µg/L 1.1%
of the EPA limit 2000 µg/L
worst single sample: 23 µg/L
3/5 SYR4 2012–2018
Chromium
10.575 µg/L 11%
of the EPA limit 100 µg/L
worst single sample: 11 µg/L
2/5 SYR4 2012–2018
TTHM
4.7805 µg/L 6%
of the EPA limit 80 µg/L
worst single sample: 4.89 µg/L
2/3 SYR4 2012–2017
Bromodichloromethane
2.2 µg/L
No EPA limit set
1/3 SYR4 2012–2014
Bromoform
0.5500 µg/L
No EPA limit set
1/3 SYR4 2012–2014
Chloroform
0.5400 µg/L
No EPA limit set
1/3 SYR4 2012–2014
Dibromochloromethane
1.6 µg/L
No EPA limit set
1/3 SYR4 2012–2014
Gross Alpha, Excl. Radon And U
2.6 pCi/L 17%
of the EPA limit 15 pCi/L
1/1 SYR4 2012
Nitrate-Nitrite
2200 µg/L 22%
of the EPA limit 10000 µg/L
1/1 SYR4 2015
Total Haloacetic Acids (HAA5)
1.5 µg/L 2.5%
of the EPA limit 60 µg/L
1/3 SYR4 2012–2017
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LORD, HEATHER
Phone
410-239-9366
Email
[email protected]

Frequently asked questions about Reservoir Trailer Park

Is Reservoir Trailer Park tap water safe to drink?

EPA monitoring detected 12 contaminants in Reservoir Trailer Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Reservoir Trailer Park's water?

EPA monitoring detected Nitrate, Lead, Barium, Chromium, TTHM, and others. The full list with the level and data source for each is above.

How many people does Reservoir Trailer Park serve?

Reservoir Trailer Park reports serving 79 people in Maryland, per its EPA record.

Has Reservoir Trailer Park had any water quality violations?

The EPA has 63 violations on file for Reservoir Trailer Park, of which 45 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.