Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2009-10-01 → 2009-10-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-10-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-10-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-10-31 |
| MCL | Health-based | Resolved | 2009-09-01 → 2009-09-30 |
| MCL | Health-based | Resolved | 2009-09-01 → 2009-09-30 |
| MCL | Health-based | Resolved | 2009-09-01 → 2009-09-30 |
| MCL | Health-based | Resolved | 2009-09-01 → 2009-09-30 |
| MR | Monitoring | Archived | 2010-03-01 → 2010-03-31 |
| MR | Monitoring | Archived | 2010-03-01 → 2010-03-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 4500 µg/L 45% of the EPA limit 10000 µg/L
worst single sample: 4800 µg/L | 86/86 | SYR4 | 2012–2015 |
| Nitrate-Nitrite | 4725 µg/L 47% of the EPA limit 10000 µg/L
worst single sample: 5230 µg/L | 36/36 | SYR4 | 2015–2019 |
| 1,1-Dichloroethylene | 3.406 µg/L 49% of the EPA limit 7 µg/L
worst single sample: 3.6 µg/L | 25/62 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 12.674 pCi/L 84% of the EPA limit 15 pCi/L
worst single sample: 16.03 pCi/L | 23/23 | SYR4 | 2012–2019 |
| Fluoride | 326 µg/L 8.2% of the EPA limit 4000 µg/L
worst single sample: 380 µg/L | 19/25 | SYR4 | 2012–2019 |
| Barium | 248 µg/L 12% of the EPA limit 2000 µg/L
worst single sample: 280 µg/L | 17/24 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 2.398 pCi/L 48% of the EPA limit 5 pCi/L
worst single sample: 2.86 pCi/L | 15/23 | SYR4 | 2012–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2023 |
| Tetrachloroethylene | 6.015 µg/L 120% of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 6.6 µg/L | 14/55 | SYR4 | 2012–2019 |
| Lithium | 27.7 µg/L No EPA limit set | 14/14 | UCMR-5 | 2024 |
| Dibromochloromethane | 4.0895 µg/L No EPA limit set
worst single sample: 7.01 µg/L | 12/35 | SYR4 | 2012–2019 |
| Bromodichloromethane | 4.279 µg/L No EPA limit set
worst single sample: 5.56 µg/L | 8/34 | SYR4 | 2012–2018 |
| Chloroform | 2.7695 µg/L No EPA limit set
worst single sample: 3.13 µg/L | 8/36 | SYR4 | 2012–2019 |
| TTHM | 14.84 µg/L 19% of the EPA limit 80 µg/L
worst single sample: 19.6 µg/L | 8/8 | SYR4 | 2012–2019 |
| Combined Uranium | 11.2093 µg/L 37% of the EPA limit 30 µg/L
worst single sample: 12.5458 µg/L | 7/7 | SYR4 | 2012–2018 |
| Di(2-ethylhexyl) Phthalate | 2.856 µg/L 48% of the EPA limit 6 µg/L
worst single sample: 2.95 µg/L | 5/14 | SYR4 | 2012–2018 |
| Total Haloacetic Acids (HAA5) | 3.056 µg/L 5.1% of the EPA limit 60 µg/L
worst single sample: 3.12 µg/L | 5/8 | SYR4 | 2012–2019 |
| Arsenic | 3 µg/L 30% of the EPA limit 10 µg/L | 4/25 | SYR4 | 2012–2019 |
| Bromoform | 3.582 µg/L No EPA limit set
worst single sample: 3.9 µg/L | 3/34 | SYR4 | 2012–2018 |
| Chromium | 5 µg/L 5% of the EPA limit 100 µg/L | 3/23 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 1.556 µg/L No EPA limit set
worst single sample: 1.58 µg/L | 2/3 | SYR4 | 2012–2014 |
| Carbon Tetrachloride | 0.5000 µg/L 10% of the EPA limit 5 µg/L | 1/62 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.54 µg/L No EPA limit set | 1/3 | SYR4 | 2012–2014 |
| Methoxychlor | 0.9100 µg/L 2.3% of the EPA limit 40 µg/L | 1/14 | SYR4 | 2012–2018 |
73 contaminants tested, none detected
Utility contact
Frequently asked questions about City of Taneytown
Is City of Taneytown tap water safe to drink?
EPA monitoring detected 30 contaminants in City of Taneytown's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in City of Taneytown's water?
EPA monitoring detected Nitrate, Nitrate-Nitrite, 1,1-Dichloroethylene, Gross Alpha, Excl. Radon And U, Fluoride, and others. The full list with the level and data source for each is above.
How many people does City of Taneytown serve?
City of Taneytown reports serving 6,750 people in Maryland, per its EPA record.
Has City of Taneytown had any water quality violations?
The EPA has 99 violations on file for City of Taneytown, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.