← Massachusetts

Tap water quality report

Attleboro Water Dept

EPA monitoring tested this supplier for 103 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

103
contaminants tested
23
detected
46,461
people served
4
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Bristol

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2018-10-01 → 2018-12-31
MCL Health-based Archived 1992-08-01 → 1992-08-31
TT Health-based Resolved 1992-01-01 → 1995-08-02
TT Health-based Resolved 1992-01-01 → 1995-08-02
MR Monitoring Archived 2006-10-01 → 2006-12-31
MR Monitoring Archived 2006-10-01 → 2006-12-31
MR Monitoring Archived 2006-10-01 → 2006-12-31
MR Monitoring Archived 2006-10-01 → 2006-12-31
MR Monitoring Archived 2006-10-01 → 2006-12-31
MR Monitoring Archived 2006-10-01 → 2006-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFHXS 0.0038 µg/L 3/7 2025
PFOA 0.0066 µg/L 2/7 2025
PFOS 0.0120 µg/L 2/7 2025
Pfhxa 0.0043 µg/L 1/7 2025
Pfpea 0.0044 µg/L 1/7 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
92.715 µg/L 116%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 110 µg/L
140/140 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
56.05 µg/L 93%
of the EPA limit 60 µg/L
worst single sample: 78.6 µg/L
140/140 SYR4 2012–2019
Bromodichloromethane
26.025 µg/L
No EPA limit set
worst single sample: 36.1 µg/L
116/116 SYR4 2013–2019
Chloroform
71 µg/L
No EPA limit set
worst single sample: 80 µg/L
116/116 SYR4 2013–2019
Dibromochloromethane
11.675 µg/L
No EPA limit set
worst single sample: 16.6 µg/L
116/116 SYR4 2013–2019
Trichloroacetic Acid
41.25 µg/L
No EPA limit set
worst single sample: 55.1 µg/L
116/116 SYR4 2013–2019
Dichloroacetic Acid
21.65 µg/L
No EPA limit set
worst single sample: 27 µg/L
115/116 SYR4 2013–2019
Bromoform
2.72 µg/L
No EPA limit set
worst single sample: 34.5 µg/L
63/116 SYR4 2013–2019
Nitrate
510 µg/L 5.1%
of the EPA limit 10000 µg/L
worst single sample: 610 µg/L
52/52 SYR4 2012–2019
Monochloroacetic Acid
2.88 µg/L
No EPA limit set
worst single sample: 5.2 µg/L
45/116 SYR4 2013–2019
Dibromoacetic Acid
2.3 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
42/116 SYR4 2013–2019
Barium
43.8 µg/L 2.2%
of the EPA limit 2000 µg/L
worst single sample: 73 µg/L
22/24 SYR4 2012–2019
Fluoride
1000 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1100 µg/L
21/24 SYR4 2012–2019
Lead
0.0013 mg/L 8.9%
of the EPA limit 0.0150 mg/L
17/17 LCR 2026
Monobromoacetic Acid
0.7940 µg/L
No EPA limit set
worst single sample: 0.8000 µg/L
4/116 SYR4 2013–2019
Nitrite
9 µg/L 0.9%
of the EPA limit 1000 µg/L
2/7 SYR4 2014–2017
Bromate
5.3 µg/L 53%
of the EPA limit 10 µg/L
1/40 SYR4 2013–2019
Copper
20 µg/L 1.5%
of the EPA limit 1300 µg/L
1/24 SYR4 2013–2019
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DENNIS MORTON
Phone
7742031850
Email
[email protected]

Frequently asked questions about Attleboro Water Dept

Is Attleboro Water Dept tap water safe to drink?

EPA monitoring detected 23 contaminants in Attleboro Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Attleboro Water Dept's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Attleboro Water Dept serve?

Attleboro Water Dept reports serving 46,461 people in Massachusetts, per its EPA record.

Has Attleboro Water Dept had any water quality violations?

The EPA has 16 violations on file for Attleboro Water Dept, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.