← Massachusetts

Tap water quality report

Dracut Water Supply District

EPA monitoring tested this supplier for 92 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

92
contaminants tested
9
detected
25,808
people served
3
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Middlesex

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
105
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2014-10-01 → 2014-10-31
MCL Health-based Archived 2014-09-01 → 2014-09-30
MCL Health-based Archived 2014-08-01 → 2014-08-31
MR Monitoring Archived 2014-10-01 → 2014-10-31
MR Monitoring Archived 2007-07-01 → 2007-09-30
MR Monitoring Archived 2007-07-01 → 2007-09-30
MR Monitoring Archived 2007-07-01 → 2007-09-30
MR Monitoring Archived 2007-07-01 → 2007-09-30
MR Monitoring Archived 2007-07-01 → 2007-09-30
MR Monitoring Archived 2007-07-01 → 2007-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFBS 0.0101 µg/L 3/8 2025
PFOA 0.0061 µg/L 3/8 2025
Pfpea 0.0031 µg/L 1/8 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1871 µg/L 19%
of the EPA limit 10000 µg/L
worst single sample: 1990 µg/L
38/38 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
25/25 LCR 2025
Barium
33.05 µg/L 1.7%
of the EPA limit 2000 µg/L
worst single sample: 33.4 µg/L
6/6 SYR4 2012–2018
Copper
15.2 µg/L 1.2%
of the EPA limit 1300 µg/L
worst single sample: 15.3 µg/L
6/6 SYR4 2017–2019
Fluoride
1462 µg/L 37%
of the EPA limit 4000 µg/L
worst single sample: 1500 µg/L
5/6 SYR4 2012–2018
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
4/6 SYR4 2012–2018
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MICHAEL SHEU
Phone
9789570441
Email
[email protected]

Frequently asked questions about Dracut Water Supply District

Is Dracut Water Supply District tap water safe to drink?

EPA monitoring detected 9 contaminants in Dracut Water Supply District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Dracut Water Supply District's water?

EPA monitoring detected Nitrate, Lead, Barium, Copper, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Dracut Water Supply District serve?

Dracut Water Supply District reports serving 25,808 people in Massachusetts, per its EPA record.

Has Dracut Water Supply District had any water quality violations?

The EPA has 105 violations on file for Dracut Water Supply District, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.