← Louisiana

Tap water quality report

Town of Gueydan Water

EPA monitoring tested this supplier for 80 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
18
detected
2,016
people served
42
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Vermilion Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

42
health-based violations
77
violations on file
13
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-08-08
TT Health-based Unaddressed 2025-08-08
TT Health-based Unaddressed 2025-08-08
TT Health-based Unaddressed 2025-08-08
TT Health-based Unaddressed 2025-08-08
TT Health-based Unaddressed 2025-08-08
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2023-07-11
TT Health-based Resolved 2023-07-11
TT Health-based Resolved 2023-07-11

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
900 µg/L 69%
of the EPA limit 1300 µg/L
worst single sample: 1400 µg/L
44/63 SYR4 2013–2019
Barium
1002.5 µg/L 50%
of the EPA limit 2000 µg/L
worst single sample: 1020 µg/L
36/37 SYR4 2012–2019
Lead
4.8 µg/L 32%
of the EPA limit 15 µg/L
worst single sample: 9 µg/L
25/63 SYR4 2013–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Chloroform
3.035 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
14/14 SYR4 2013–2019
TTHM
3.675 µg/L 4.6%
of the EPA limit 80 µg/L
worst single sample: 4 µg/L
14/14 SYR4 2013–2019
Dichloroacetic Acid
5.8 µg/L
No EPA limit set
worst single sample: 9.1 µg/L
13/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
7.78 µg/L 13%
of the EPA limit 60 µg/L
worst single sample: 10.9 µg/L
13/14 SYR4 2013–2019
Dibromoacetic Acid
1.765 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
8/14 SYR4 2013–2019
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
6/6 SYR4 2014–2017
Combined Radium (-226 And -228)
2.5665 pCi/L 51%
of the EPA limit 5 pCi/L
worst single sample: 2.64 pCi/L
4/4 SYR4 2017–2018
Nitrate-Nitrite
31 µg/L 0.3%
of the EPA limit 10000 µg/L
4/30 SYR4 2012–2019
Bromodichloromethane
0.9560 µg/L
No EPA limit set
worst single sample: 0.9700 µg/L
3/14 SYR4 2013–2019
Chromium
10 µg/L 10%
of the EPA limit 100 µg/L
3/7 SYR4 2014–2017
Di(2-ethylhexyl) Phthalate
1.034 µg/L 17%
of the EPA limit 6 µg/L
worst single sample: 1.04 µg/L
3/6 SYR4 2014–2017
Trichloroacetic Acid
0.9600 µg/L
No EPA limit set
worst single sample: 1 µg/L
3/14 SYR4 2013–2019
P-Dichlorobenzene
0.2695 µg/L 0.4%
of the EPA limit 75 µg/L
worst single sample: 0.2700 µg/L
2/6 SYR4 2014–2017
Monochloroacetic Acid
1.8 µg/L
No EPA limit set
1/14 SYR4 2013–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
REESE, JUDE
Phone
337-536-9415
Email
[email protected]

Frequently asked questions about Town of Gueydan Water

Is Town of Gueydan Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Town of Gueydan Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Town of Gueydan Water's water?

EPA monitoring detected Copper, Barium, Lead, Lead, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Town of Gueydan Water serve?

Town of Gueydan Water reports serving 2,016 people in Louisiana, per its EPA record.

Has Town of Gueydan Water had any water quality violations?

The EPA has 77 violations on file for Town of Gueydan Water, of which 42 are health-based (a contaminant limit or required treatment was breached) and 13 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.