Tap water quality report

Consolidated Waterworks District 2

EPA monitoring tested this supplier for 111 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

111
contaminants tested
15
detected
3,498
people served
7
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Morehouse Parish

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
16
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
MCL Health-based Archived 2012-09-01 → 2012-09-30
MCL Health-based Archived 2012-09-01 → 2012-09-30
MCL Health-based Archived 2012-09-01 → 2012-09-30
MCL Health-based Archived 2002-11-01 → 2002-11-30
MCL Health-based Archived 2002-11-01 → 2002-11-30
MCL Health-based Archived 2002-11-01 → 2002-11-30
RPT Monitoring Resolved 2024-10-17
MR Monitoring Resolved 2013-09-01 → 2014-08-31
MR Monitoring Resolved 2013-09-01 → 2014-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
685 µg/L 53%
of the EPA limit 1300 µg/L
worst single sample: 1000 µg/L
44/63 SYR4 2013–2019
Lead
2 µg/L 13%
of the EPA limit 15 µg/L
worst single sample: 6 µg/L
42/63 SYR4 2013–2019
Nitrate-Nitrite
409 µg/L 4.1%
of the EPA limit 10000 µg/L
worst single sample: 410 µg/L
22/32 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Fluoride
330 µg/L 8.3%
of the EPA limit 4000 µg/L
6/6 SYR4 2014–2017
Arsenic
1.56 µg/L 16%
of the EPA limit 10 µg/L
worst single sample: 1.7 µg/L
5/6 SYR4 2014–2017
Dibromoacetic Acid
0.9150 µg/L
No EPA limit set
worst single sample: 0.9300 µg/L
4/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.2125 µg/L 2%
of the EPA limit 60 µg/L
worst single sample: 1.28 µg/L
4/14 SYR4 2013–2019
Barium
97 µg/L 4.9%
of the EPA limit 2000 µg/L
worst single sample: 99 µg/L
3/6 SYR4 2014–2017
Combined Radium (-226 And -228)
0.6342 pCi/L 13%
of the EPA limit 5 pCi/L
worst single sample: 0.6390 pCi/L
3/3 SYR4 2017
Di(2-ethylhexyl) Phthalate
1.388 µg/L 23%
of the EPA limit 6 µg/L
worst single sample: 1.45 µg/L
3/6 SYR4 2014–2017
Dibromochloromethane
0.4250 µg/L
No EPA limit set
worst single sample: 0.4300 µg/L
3/14 SYR4 2013–2019
TTHM
1.075 µg/L 1.3%
of the EPA limit 80 µg/L
worst single sample: 1.12 µg/L
3/14 SYR4 2013–2019
Bromoform
0.6715 µg/L
No EPA limit set
worst single sample: 0.6900 µg/L
2/14 SYR4 2013–2019
Dichloroacetic Acid
0.3500 µg/L
No EPA limit set
1/14 SYR4 2013–2019
96 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SISTRUNK, STEVE
Phone
318-281-2989
Email
[email protected]

Frequently asked questions about Consolidated Waterworks District 2

Is Consolidated Waterworks District 2 tap water safe to drink?

EPA monitoring detected 15 contaminants in Consolidated Waterworks District 2's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Consolidated Waterworks District 2's water?

EPA monitoring detected Copper, Lead, Nitrate-Nitrite, Lead, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Consolidated Waterworks District 2 serve?

Consolidated Waterworks District 2 reports serving 3,498 people in Louisiana, per its EPA record.

Has Consolidated Waterworks District 2 had any water quality violations?

The EPA has 16 violations on file for Consolidated Waterworks District 2, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.