Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2024-10-17 |
| TT | Health-based | Unaddressed | 2024-10-17 |
| TT | Health-based | Unaddressed | 2024-10-17 |
| TT | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| TT | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| TT | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| TT | Health-based | Resolved | 2024-01-01 → 2024-03-31 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-07-31 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-07-31 |
| MCL | Health-based | Resolved | 2012-07-01 → 2012-07-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 61.98 µg/L 77% of the EPA limit 80 µg/L
worst single sample: 66.4 µg/L | 127/127 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 51.58 µg/L 86% of the EPA limit 60 µg/L
worst single sample: 62 µg/L | 127/127 | SYR4 | 2012–2019 |
| Copper | 90.5 µg/L 7% of the EPA limit 1300 µg/L
worst single sample: 220 µg/L | 60/69 | SYR4 | 2012–2019 |
| Nitrate | 800 µg/L 8% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Fluoride | 1000 µg/L 25% of the EPA limit 4000 µg/L | 15/15 | SYR4 | 2012–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2023 |
| Barium | 20 µg/L 1% of the EPA limit 2000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Lead | 14 µg/L 93% of the EPA limit 15 µg/L | 8/61 | SYR4 | 2014–2017 |
| Benzo(A)Pyrene | 0.0470 µg/L 24% of the EPA limit 0.2000 µg/L | 1/5 | SYR4 | 2014–2019 |
| Cyanide | 12 µg/L 6% of the EPA limit 200 µg/L | 1/8 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 1.3 pCi/L 26% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2016 |
87 contaminants tested, none detected
Utility contact
Frequently asked questions about Versailles Water
Is Versailles Water tap water safe to drink?
EPA monitoring detected 13 contaminants in Versailles Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Versailles Water's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Fluoride, and others. The full list with the level and data source for each is above.
How many people does Versailles Water serve?
Versailles Water reports serving 17,822 people in Kentucky, per its EPA record.
Has Versailles Water had any water quality violations?
The EPA has 362 violations on file for Versailles Water, of which 18 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.