Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2015-07-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-07-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-07-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2015-07-01 → 2015-09-30 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| MCL | Health-based | Resolved | 2014-01-01 → 2014-03-31 |
| TT | Health-based | Resolved | 2004-10-01 → 2004-10-31 |
| TT | Health-based | Resolved | 2004-10-01 → 2004-10-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 85.1 µg/L 106% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 136 µg/L | 259/259 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 64 µg/L 107% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 84 µg/L | 259/259 | SYR4 | 2012–2019 |
| Copper | 121.6 µg/L 9.4% of the EPA limit 1300 µg/L
worst single sample: 215 µg/L | 98/98 | SYR4 | 2012–2019 |
| Chlorite | 799.5 µg/L 80% of the EPA limit 1000 µg/L
worst single sample: 830 µg/L | 62/63 | SYR4 | 2012–2014 |
| Nitrate | 900 µg/L 9% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Fluoride | 800 µg/L 20% of the EPA limit 4000 µg/L | 15/16 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2024 |
| Barium | 26 µg/L 1.3% of the EPA limit 2000 µg/L | 8/8 | SYR4 | 2012–2019 |
| Lead | 7.5 µg/L 50% of the EPA limit 15 µg/L
worst single sample: 9 µg/L | 6/90 | SYR4 | 2012–2018 |
| Atrazine | 0.5700 µg/L 19% of the EPA limit 3 µg/L
worst single sample: 0.6000 µg/L | 4/11 | SYR4 | 2012–2017 |
| Mercury | 0.2000 µg/L 10% of the EPA limit 2 µg/L | 2/8 | SYR4 | 2012–2019 |
| Arsenic | 0.3000 µg/L 3% of the EPA limit 10 µg/L | 1/8 | SYR4 | 2012–2019 |
| Chlorobenzene | 0.7000 µg/L 0.7% of the EPA limit 100 µg/L | 1/11 | SYR4 | 2012–2019 |
| Chromium | 0.7000 µg/L 0.7% of the EPA limit 100 µg/L | 1/8 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 2.3 pCi/L 46% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
| Selenium | 3 µg/L 6% of the EPA limit 50 µg/L | 1/8 | SYR4 | 2012–2019 |
82 contaminants tested, none detected
Utility contact
Frequently asked questions about Paducah Water Works
Is Paducah Water Works tap water safe to drink?
EPA monitoring detected 21 contaminants in Paducah Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Paducah Water Works's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Chlorite, Nitrate, and others. The full list with the level and data source for each is above.
How many people does Paducah Water Works serve?
Paducah Water Works reports serving 65,004 people in Kentucky, per its EPA record.
Has Paducah Water Works had any water quality violations?
The EPA has 133 violations on file for Paducah Water Works, of which 16 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.