← Kentucky

Tap water quality report

Adairville Water Works

EPA monitoring tested this supplier for 35 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

35
contaminants tested
5
detected
787
people served
8
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Logan

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
37
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2001-10-01 → 2001-10-31
TT Health-based Resolved 2001-10-01 → 2001-10-31
TT Health-based Resolved 2001-10-01 → 2001-10-31
TT Health-based Resolved 2001-10-01 → 2001-10-31
MCL Health-based Resolved 1994-04-05 → 1994-05-04
MCL Health-based Resolved 1994-04-05 → 1994-05-04
MCL Health-based Resolved 1994-04-05 → 1994-05-04
MCL Health-based Resolved 1994-04-05 → 1994-05-04
Other Monitoring Resolved 2015-10-12
Other Monitoring Resolved 2015-10-12

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
90.7 µg/L 113%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 103.6 µg/L
46/46 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
42.625 µg/L 71%
of the EPA limit 60 µg/L
worst single sample: 47 µg/L
46/46 SYR4 2014–2019
Copper
87.6 µg/L 6.7%
of the EPA limit 1300 µg/L
worst single sample: 93.3 µg/L
20/20 SYR4 2014–2017
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Lead
1.26 µg/L 8.4%
of the EPA limit 15 µg/L
worst single sample: 1.3 µg/L
5/20 SYR4 2014–2017
30 contaminants tested, none detected
11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaHfpo-DaNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaLithium

Utility contact

Contact
TAYLOR, STEPHEN L
Phone
270-772-0846
Email
[email protected]

Frequently asked questions about Adairville Water Works

Is Adairville Water Works tap water safe to drink?

EPA monitoring detected 5 contaminants in Adairville Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Adairville Water Works's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Lead, Lead. The full list with the level and data source for each is above.

How many people does Adairville Water Works serve?

Adairville Water Works reports serving 787 people in Kentucky, per its EPA record.

Has Adairville Water Works had any water quality violations?

The EPA has 37 violations on file for Adairville Water Works, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.