Compliance record
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Fluoride | 768.5 µg/L 19% of the EPA limit 4000 µg/L
worst single sample: 920 µg/L | 34/34 | SYR4 | 2012–2019 |
| Copper | 1220 µg/L 94% of the EPA limit 1300 µg/L
worst single sample: 2000 µg/L | 33/33 | SYR4 | 2012–2018 |
| Nitrate | 987 µg/L 9.9% of the EPA limit 10000 µg/L
worst single sample: 990 µg/L | 22/22 | SYR4 | 2012–2019 |
| Lead | 5.515 µg/L 37% of the EPA limit 15 µg/L
worst single sample: 10 µg/L | 14/33 | SYR4 | 2012–2018 |
| Lead | 0.0012 mg/L 8% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2024 |
| Bromodichloromethane | 4.04 µg/L No EPA limit set
worst single sample: 4.1 µg/L | 7/7 | SYR4 | 2012–2019 |
| Chloroform | 5.71 µg/L No EPA limit set
worst single sample: 6.1 µg/L | 7/7 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.5 µg/L No EPA limit set
worst single sample: 3.8 µg/L | 7/7 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 2.84 µg/L No EPA limit set
worst single sample: 3.2 µg/L | 7/7 | SYR4 | 2012–2019 |
| TTHM | 13.7 µg/L 17% of the EPA limit 80 µg/L
worst single sample: 14 µg/L | 7/7 | SYR4 | 2012–2019 |
| Bromoform | 1.161 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 4/7 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 0.9695 µg/L No EPA limit set
worst single sample: 0.9800 µg/L | 4/7 | SYR4 | 2012–2019 |
| Arsenic | 2.28 µg/L 23% of the EPA limit 10 µg/L
worst single sample: 2.3 µg/L | 3/3 | SYR4 | 2012–2018 |
| Barium | 72.9 µg/L 3.6% of the EPA limit 2000 µg/L
worst single sample: 73 µg/L | 3/3 | SYR4 | 2012–2018 |
| Selenium | 4.29 µg/L 8.6% of the EPA limit 50 µg/L
worst single sample: 4.3 µg/L | 3/3 | SYR4 | 2012–2018 |
| Total Haloacetic Acids (HAA5) | 4.1 µg/L 6.8% of the EPA limit 60 µg/L
worst single sample: 4.2 µg/L | 3/7 | SYR4 | 2012–2019 |
| Chromium | 3.76 µg/L 3.8% of the EPA limit 100 µg/L
worst single sample: 3.8 µg/L | 2/3 | SYR4 | 2012–2018 |
| Lithium | 17 µg/L No EPA limit set | 2/2 | UCMR-5 | 2023 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2017 |
| Monobromoacetic Acid | 0.5400 µg/L No EPA limit set | 1/7 | SYR4 | 2012–2019 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Maize, City of
Is Maize, City of tap water safe to drink?
EPA monitoring detected 20 contaminants in Maize, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Maize, City of's water?
EPA monitoring detected Fluoride, Copper, Nitrate, Lead, Lead, and others. The full list with the level and data source for each is above.
How many people does Maize, City of serve?
Maize, City of reports serving 6,060 people in Kansas, per its EPA record.
Has Maize, City of had any water quality violations?
The EPA has no formal drinking-water violations on file for Maize, City of.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.