Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Unaddressed | 2026-01-01 → 2026-12-31 |
| MCL | Health-based | Resolved | 1996-01-01 → 1996-03-31 |
| MCL | Health-based | Resolved | 1996-01-01 → 1996-03-31 |
| MCL | Health-based | Resolved | 1996-01-01 → 1996-03-31 |
| MCL | Health-based | Resolved | 1996-01-01 → 1996-03-31 |
| MCL | Health-based | Resolved | 1995-10-01 → 1995-12-31 |
| MCL | Health-based | Resolved | 1995-10-01 → 1995-12-31 |
| MCL | Health-based | Resolved | 1995-10-01 → 1995-12-31 |
| MCL | Health-based | Resolved | 1995-10-01 → 1995-12-31 |
| MCL | Health-based | Resolved | 1995-07-01 → 1995-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 5800 µg/L 58% of the EPA limit 10000 µg/L | 20/20 | SYR4 | 2012–2019 |
| Copper | 988 µg/L 76% of the EPA limit 1300 µg/L
worst single sample: 1000 µg/L | 13/13 | SYR4 | 2014–2017 |
| Lead | 5.415 µg/L 36% of the EPA limit 15 µg/L
worst single sample: 6.9 µg/L | 10/13 | SYR4 | 2014–2017 |
| Lead | 0.0054 mg/L 36% of the EPA limit 0.0150 mg/L | 7/7 | LCR | 2023 |
| Bromodichloromethane | 2.63 µg/L No EPA limit set
worst single sample: 2.7 µg/L | 3/3 | SYR4 | 2014–2019 |
| Chloroform | 1.48 µg/L No EPA limit set
worst single sample: 1.5 µg/L | 3/3 | SYR4 | 2014–2019 |
| Dibromochloromethane | 3.56 µg/L No EPA limit set
worst single sample: 3.7 µg/L | 3/3 | SYR4 | 2014–2019 |
| Dichloroacetic Acid | 1.47 µg/L No EPA limit set
worst single sample: 1.5 µg/L | 3/3 | SYR4 | 2014–2019 |
| TTHM | 9.69 µg/L 12% of the EPA limit 80 µg/L
worst single sample: 10 µg/L | 3/3 | SYR4 | 2014–2019 |
| Barium | 179.5 µg/L 9% of the EPA limit 2000 µg/L
worst single sample: 180 µg/L | 2/2 | SYR4 | 2014–2017 |
| Bromoform | 2.345 µg/L No EPA limit set
worst single sample: 2.4 µg/L | 2/3 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 1.495 µg/L No EPA limit set
worst single sample: 1.5 µg/L | 2/3 | SYR4 | 2014–2019 |
| Fluoride | 366.5 µg/L 9.2% of the EPA limit 4000 µg/L
worst single sample: 370 µg/L | 2/2 | SYR4 | 2014–2017 |
| Total Haloacetic Acids (HAA5) | 2.895 µg/L 4.8% of the EPA limit 60 µg/L
worst single sample: 2.9 µg/L | 2/3 | SYR4 | 2014–2019 |
| Chromium | 6.7 µg/L 6.7% of the EPA limit 100 µg/L | 1/2 | SYR4 | 2014–2017 |
| Combined Radium (-226 And -228) | 0.9000 pCi/L 18% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
| Selenium | 4.9 µg/L 9.8% of the EPA limit 50 µg/L | 1/2 | SYR4 | 2014–2017 |
33 contaminants tested, none detected
Utility contact
Frequently asked questions about Axtell, City of
Is Axtell, City of tap water safe to drink?
EPA monitoring detected 17 contaminants in Axtell, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Axtell, City of's water?
EPA monitoring detected Nitrate, Copper, Lead, Lead, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Axtell, City of serve?
Axtell, City of reports serving 398 people in Kansas, per its EPA record.
Has Axtell, City of had any water quality violations?
The EPA has 39 violations on file for Axtell, City of, of which 39 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.