← Kansas

Tap water quality report

Florence, City of

EPA monitoring tested this supplier for 62 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

62
contaminants tested
22
detected
387
people served
47
health-based violations
Water source
Ground water under surface influence
Ownership
Local government
Counties served
Marion

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

47
health-based violations
163
violations on file
3
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1014.5 µg/L 10%
of the EPA limit 10000 µg/L
worst single sample: 1100 µg/L
30/30 SYR4 2012–2019
Dibromoacetic Acid
2.695 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
28/28 SYR4 2012–2019
Dichloroacetic Acid
44.3 µg/L
No EPA limit set
worst single sample: 51 µg/L
28/28 SYR4 2012–2019
Trichloroacetic Acid
61.15 µg/L
No EPA limit set
worst single sample: 73 µg/L
28/28 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
107 µg/L 178%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 130 µg/L
27/28 SYR4 2012–2019
Chloroform
90.5 µg/L
No EPA limit set
worst single sample: 100 µg/L
26/26 SYR4 2012–2019
TTHM
107.25 µg/L 134%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 130 µg/L
26/26 SYR4 2012–2019
Bromodichloromethane
19 µg/L
No EPA limit set
worst single sample: 23 µg/L
25/26 SYR4 2012–2019
Dibromochloromethane
8.16 µg/L
No EPA limit set
worst single sample: 8.6 µg/L
25/26 SYR4 2012–2019
Copper
588 µg/L 45%
of the EPA limit 1300 µg/L
worst single sample: 820 µg/L
23/23 SYR4 2012–2019
Bromoform
1.425 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
16/26 SYR4 2012–2019
Lead
0.0043 mg/L 29%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Lead
7.44 µg/L 50%
of the EPA limit 15 µg/L
worst single sample: 12 µg/L
13/23 SYR4 2012–2019
Monobromoacetic Acid
1.8 µg/L
No EPA limit set
12/28 SYR4 2012–2019
Barium
206.5 µg/L 10%
of the EPA limit 2000 µg/L
worst single sample: 210 µg/L
8/8 SYR4 2012–2019
Fluoride
415.5 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 440 µg/L
8/8 SYR4 2012–2019
Selenium
1.93 µg/L 3.9%
of the EPA limit 50 µg/L
worst single sample: 2 µg/L
8/8 SYR4 2012–2019
Monochloroacetic Acid
4.58 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
7/28 SYR4 2012–2019
Chromium
4.36 µg/L 4.4%
of the EPA limit 100 µg/L
worst single sample: 4.6 µg/L
5/8 SYR4 2012–2019
Arsenic
1.485 µg/L 15%
of the EPA limit 10 µg/L
worst single sample: 1.5 µg/L
2/8 SYR4 2012–2019
Atrazine
0.3300 µg/L 11%
of the EPA limit 3 µg/L
1/2 SYR4 2014–2017
Combined Radium (-226 And -228)
1.2 pCi/L 24%
of the EPA limit 5 pCi/L
1/1 SYR4 2015
40 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GAYLE, ROBERT
Phone
620-878-4296
Email
[email protected]

Frequently asked questions about Florence, City of

Is Florence, City of tap water safe to drink?

EPA monitoring detected 22 contaminants in Florence, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Florence, City of's water?

EPA monitoring detected Nitrate, Dibromoacetic Acid, Dichloroacetic Acid, Trichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Florence, City of serve?

Florence, City of reports serving 387 people in Kansas, per its EPA record.

Has Florence, City of had any water quality violations?

The EPA has 163 violations on file for Florence, City of, of which 47 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.