Tap water quality report

Linn Co Rwd 3

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
710
people served
103
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Linn

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

103
health-based violations
166
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-04-01 → 2007-06-30
MCL Health-based Resolved 2007-01-01 → 2007-03-31
MCL Health-based Resolved 2007-01-01 → 2007-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
358 µg/L 28%
of the EPA limit 1300 µg/L
worst single sample: 600 µg/L
30/30 SYR4 2013–2019
Bromodichloromethane
13.8 µg/L
No EPA limit set
worst single sample: 18 µg/L
25/25 SYR4 2013–2019
Chloroform
51.8 µg/L
No EPA limit set
worst single sample: 62 µg/L
25/25 SYR4 2013–2019
Dichloroacetic Acid
26 µg/L
No EPA limit set
worst single sample: 28 µg/L
25/25 SYR4 2013–2019
TTHM
67 µg/L 84%
of the EPA limit 80 µg/L
worst single sample: 75 µg/L
25/25 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
46.8 µg/L 78%
of the EPA limit 60 µg/L
worst single sample: 52 µg/L
25/25 SYR4 2013–2019
Trichloroacetic Acid
19 µg/L
No EPA limit set
worst single sample: 21 µg/L
25/25 SYR4 2013–2019
Lead
6.26 µg/L 42%
of the EPA limit 15 µg/L
worst single sample: 8.9 µg/L
22/30 SYR4 2013–2019
Dibromochloromethane
3.5 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
21/25 SYR4 2013–2019
Dibromoacetic Acid
1.59 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
15/25 SYR4 2013–2019
Monochloroacetic Acid
6.44 µg/L
No EPA limit set
worst single sample: 7.4 µg/L
13/25 SYR4 2013–2019
Lead
0.0110 mg/L 73%
of the EPA limit 0.0150 mg/L
8/8 LCR 2025
Monobromoacetic Acid
1.45 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
6/25 SYR4 2013–2019
Bromoform
0.7000 µg/L
No EPA limit set
1/25 SYR4 2013–2019

Utility contact

Contact
LUEKER, AIMEE
Phone
785-204-1675
Email
[email protected]

Frequently asked questions about Linn Co Rwd 3

Is Linn Co Rwd 3 tap water safe to drink?

EPA monitoring detected 14 contaminants in Linn Co Rwd 3's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Linn Co Rwd 3's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Linn Co Rwd 3 serve?

Linn Co Rwd 3 reports serving 710 people in Kansas, per its EPA record.

Has Linn Co Rwd 3 had any water quality violations?

The EPA has 166 violations on file for Linn Co Rwd 3, of which 103 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.