← Kansas

Tap water quality report

Dodge City, City of

EPA monitoring tested this supplier for 83 contaminants and detected 29. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

83
contaminants tested
29
detected
27,104
people served
50
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Ford

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

50
health-based violations
105
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-01-01 → 2023-12-31
MCL Health-based Resolved 2023-01-01 → 2023-12-31
MCL Health-based Resolved 2023-01-01 → 2023-12-31
MCL Health-based Resolved 2023-01-01 → 2023-12-31
MCL Health-based Resolved 2013-12-01 → 2013-12-31
MCL Health-based Resolved 2013-12-01 → 2013-12-31
MCL Health-based Resolved 2013-12-01 → 2013-12-31
MCL Health-based Resolved 2013-12-01 → 2013-12-31
MCL Health-based Resolved 2013-12-01 → 2013-12-31
MCL Health-based Resolved 2010-01-01 → 2010-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0037 µg/L 1/28 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
7800 µg/L 78%
of the EPA limit 10000 µg/L
worst single sample: 21000 µg/L
384/384 SYR4 2012–2019
Copper
214 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 570 µg/L
133/133 SYR4 2013–2019
Bromoform
7.89 µg/L
No EPA limit set
worst single sample: 12 µg/L
78/98 SYR4 2012–2019
Dibromochloromethane
6.48 µg/L
No EPA limit set
worst single sample: 8.3 µg/L
75/98 SYR4 2012–2019
Dibromoacetic Acid
2.5 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
73/98 SYR4 2012–2019
TTHM
34.4 µg/L 43%
of the EPA limit 80 µg/L
worst single sample: 79 µg/L
69/98 SYR4 2012–2019
Bromodichloromethane
6.86 µg/L
No EPA limit set
worst single sample: 14 µg/L
49/98 SYR4 2012–2019
Arsenic
4.09 µg/L 41%
of the EPA limit 10 µg/L
worst single sample: 4.8 µg/L
43/43 SYR4 2013–2019
Barium
216 µg/L 11%
of the EPA limit 2000 µg/L
worst single sample: 230 µg/L
43/43 SYR4 2013–2019
Selenium
22.7 µg/L 45%
of the EPA limit 50 µg/L
worst single sample: 29 µg/L
42/43 SYR4 2013–2019
Fluoride
2500 µg/L 63%
of the EPA limit 4000 µg/L
worst single sample: 2700 µg/L
41/43 SYR4 2013–2019
Chromium
3.605 µg/L 3.6%
of the EPA limit 100 µg/L
worst single sample: 4.5 µg/L
38/43 SYR4 2013–2019
Lead
16 µg/L 107%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 38 µg/L
31/131 SYR4 2013–2019
Lithium
166 µg/L
No EPA limit set
28/28 UCMR-5 2024
Chloroform
51.4 µg/L
No EPA limit set
worst single sample: 58 µg/L
24/98 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
15.185 µg/L 25%
of the EPA limit 60 µg/L
worst single sample: 25 µg/L
24/98 SYR4 2012–2019
Dichloroacetic Acid
9.77 µg/L
No EPA limit set
worst single sample: 14 µg/L
19/98 SYR4 2012–2019
Atrazine
1.783 µg/L 59%
of the EPA limit 3 µg/L
worst single sample: 4.1 µg/L
15/36 SYR4 2013–2019
Monobromoacetic Acid
2.39 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
15/98 SYR4 2012–2019
Combined Radium (-226 And -228)
1.4 pCi/L 28%
of the EPA limit 5 pCi/L
worst single sample: 2 pCi/L
13/26 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Xylenes, Total
19 µg/L 0.2%
of the EPA limit 10000 µg/L
worst single sample: 20 µg/L
5/44 SYR4 2012–2019
Ethylbenzene
3.27 µg/L 0.5%
of the EPA limit 700 µg/L
worst single sample: 3.3 µg/L
4/44 SYR4 2012–2019
Trichloroacetic Acid
4.76 µg/L
No EPA limit set
worst single sample: 5 µg/L
4/98 SYR4 2012–2019
Combined Uranium
12.915 µg/L 43%
of the EPA limit 30 µg/L
worst single sample: 13 µg/L
2/2 SYR4 2013–2014
Gross Alpha, Excl. Radon And U
6.96 pCi/L 46%
of the EPA limit 15 pCi/L
worst single sample: 7 pCi/L
2/2 SYR4 2013–2014
Trichloroethylene
0.5500 µg/L 11%
of the EPA limit 5 µg/L
2/44 SYR4 2012–2019
Monochloroacetic Acid
3 µg/L
No EPA limit set
1/98 SYR4 2012–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideDichloromethaneEthylene DibromideHfpo-DaLassoMercuryNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaStyreneTetrachloroethyleneThallium, TotalTolueneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KELLER, COREY
Phone
620-225-8170
Email
[email protected]

Frequently asked questions about Dodge City, City of

Is Dodge City, City of tap water safe to drink?

EPA monitoring detected 29 contaminants in Dodge City, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Dodge City, City of's water?

EPA monitoring detected Nitrate, Copper, Bromoform, Dibromochloromethane, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Dodge City, City of serve?

Dodge City, City of reports serving 27,104 people in Kansas, per its EPA record.

Has Dodge City, City of had any water quality violations?

The EPA has 105 violations on file for Dodge City, City of, of which 50 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.