Tap water quality report

Doniphan Co Rwd 5

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
1,457
people served
4
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Doniphan

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
63
violations on file
1
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MCL Health-based Resolved 2003-09-01 → 2003-09-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30
MR Monitoring Resolved 2025-04-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
26 µg/L
No EPA limit set
worst single sample: 29 µg/L
30/30 SYR4 2012–2019
Chloroform
87.55 µg/L
No EPA limit set
worst single sample: 100 µg/L
30/30 SYR4 2012–2019
Dichloroacetic Acid
33.9 µg/L
No EPA limit set
worst single sample: 52 µg/L
30/30 SYR4 2012–2019
TTHM
120 µg/L 150%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 140 µg/L
30/30 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
62.6 µg/L 104%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 100 µg/L
29/30 SYR4 2012–2019
Trichloroacetic Acid
20.2 µg/L
No EPA limit set
worst single sample: 43 µg/L
29/30 SYR4 2012–2019
Copper
280.5 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 290 µg/L
20/20 SYR4 2014–2017
Dibromochloromethane
9.2 µg/L
No EPA limit set
worst single sample: 9.5 µg/L
16/30 SYR4 2012–2019
Monochloroacetic Acid
5.12 µg/L
No EPA limit set
worst single sample: 7.1 µg/L
13/30 SYR4 2012–2019
Dibromoacetic Acid
2.545 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
12/30 SYR4 2012–2019
Monobromoacetic Acid
3.14 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
9/30 SYR4 2012–2019
Lead
0.0018 mg/L 12%
of the EPA limit 0.0150 mg/L
8/8 LCR 2023
Bromoform
0.7470 µg/L
No EPA limit set
worst single sample: 0.7600 µg/L
3/30 SYR4 2012–2019
Lead
1.2 µg/L 8%
of the EPA limit 15 µg/L
1/20 SYR4 2014–2017

Frequently asked questions about Doniphan Co Rwd 5

Is Doniphan Co Rwd 5 tap water safe to drink?

EPA monitoring detected 14 contaminants in Doniphan Co Rwd 5's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Doniphan Co Rwd 5's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Doniphan Co Rwd 5 serve?

Doniphan Co Rwd 5 reports serving 1,457 people, per its EPA record.

Has Doniphan Co Rwd 5 had any water quality violations?

The EPA has 63 violations on file for Doniphan Co Rwd 5, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.