← Indiana

Tap water quality report

Emerald Ii

EPA monitoring tested this supplier for 67 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

67
contaminants tested
10
detected
98
people served
46
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Shelby

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

46
health-based violations
134
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2008-04-01 → 2008-04-30
MCL Health-based Resolved 2007-09-01 → 2007-09-30
MCL Health-based Resolved 2007-09-01 → 2007-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4470 µg/L 45%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2024
Copper
16.8 µg/L 1.3%
of the EPA limit 1300 µg/L
worst single sample: 19 µg/L
5/5 SYR4 2018
Total Haloacetic Acids (HAA5)
4.435 µg/L 7.4%
of the EPA limit 60 µg/L
worst single sample: 4.6 µg/L
4/7 SYR4 2012–2018
Fluoride
291.5 µg/L 7.3%
of the EPA limit 4000 µg/L
worst single sample: 300 µg/L
3/3 SYR4 2014–2018
Barium
130.7 µg/L 6.5%
of the EPA limit 2000 µg/L
worst single sample: 131 µg/L
2/2 SYR4 2014–2017
TTHM
2.795 µg/L 3.5%
of the EPA limit 80 µg/L
worst single sample: 2.8 µg/L
2/7 SYR4 2012–2018
Cyanide
31 µg/L 16%
of the EPA limit 200 µg/L
1/2 SYR4 2014–2017
Gross Alpha, Excl. Radon And U
1.1 pCi/L 7.3%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Lead
2.3 µg/L 15%
of the EPA limit 15 µg/L
1/5 SYR4 2018
57 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HYNES, STEPHEN
Phone
260-797-2375
Email
[email protected]

Frequently asked questions about Emerald Ii

Is Emerald Ii tap water safe to drink?

EPA monitoring detected 10 contaminants in Emerald Ii's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Emerald Ii's water?

EPA monitoring detected Nitrate, Lead, Copper, Total Haloacetic Acids (HAA5), Fluoride, and others. The full list with the level and data source for each is above.

How many people does Emerald Ii serve?

Emerald Ii reports serving 98 people in Indiana, per its EPA record.

Has Emerald Ii had any water quality violations?

The EPA has 134 violations on file for Emerald Ii, of which 46 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.