Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-07-01 → 2016-09-30 |
| MCL | Health-based | Resolved | 2016-04-01 → 2016-06-30 |
| MCL | Health-based | Resolved | 2016-04-01 → 2016-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 92.925 µg/L 116% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 130 µg/L | 156/156 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 87.51 µg/L 146% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 149 µg/L | 155/156 | SYR4 | 2012–2019 |
| Copper | 135.25 µg/L 10% of the EPA limit 1300 µg/L
worst single sample: 237 µg/L | 30/30 | SYR4 | 2017 |
| Nitrate | 818.5 µg/L 8.2% of the EPA limit 10000 µg/L
worst single sample: 830 µg/L | 22/28 | SYR4 | 2012–2019 |
| Lead | 0.0016 mg/L 11% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2023 |
| Lead | 1.77 µg/L 12% of the EPA limit 15 µg/L
worst single sample: 2.1 µg/L | 12/30 | SYR4 | 2017 |
| Fluoride | 1055 µg/L 26% of the EPA limit 4000 µg/L
worst single sample: 1100 µg/L | 10/10 | SYR4 | 2012–2019 |
| Barium | 55.455 µg/L 2.8% of the EPA limit 2000 µg/L
worst single sample: 57.8 µg/L | 8/10 | SYR4 | 2012–2019 |
| Atrazine | 165.15 µg/L 5505% of the EPA limit, at the 95th percentile of samples — 3 µg/L
worst single sample: 220 µg/L | 6/39 | SYR4 | 2012–2019 |
| Simazine | 0.3850 µg/L 9.6% of the EPA limit 4 µg/L
worst single sample: 0.4000 µg/L | 4/39 | SYR4 | 2012–2019 |
| Arsenic | 57.37 µg/L 574% of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 60.3 µg/L | 2/10 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 0.9000 µg/L 15% of the EPA limit 6 µg/L | 2/39 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 594.5 µg/L 5.9% of the EPA limit 10000 µg/L
worst single sample: 620 µg/L | 2/2 | SYR4 | 2018 |
| Gross Alpha, Excl. Radon And U | 0.2590 pCi/L 1.7% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2016 |
| Hexachlorocyclopentadiene | 0.1000 µg/L 0.2% of the EPA limit 50 µg/L | 1/35 | SYR4 | 2012–2018 |
90 contaminants tested, none detected
Utility contact
Frequently asked questions about Stucker Fork Water Utility
Is Stucker Fork Water Utility tap water safe to drink?
EPA monitoring detected 15 contaminants in Stucker Fork Water Utility's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Stucker Fork Water Utility's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Lead, and others. The full list with the level and data source for each is above.
How many people does Stucker Fork Water Utility serve?
Stucker Fork Water Utility reports serving 17,718 people in Indiana, per its EPA record.
Has Stucker Fork Water Utility had any water quality violations?
The EPA has 632 violations on file for Stucker Fork Water Utility, of which 168 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.