← Indiana

Tap water quality report

Mount Vernon Water Works

EPA monitoring tested this supplier for 103 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

103
contaminants tested
22
detected
6,426
people served
188
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Posey

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

188
health-based violations
614
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2012-04-01 → 2012-04-30
TT Health-based Resolved 2012-04-01 → 2012-04-30
TT Health-based Resolved 2012-04-01 → 2012-04-30
TT Health-based Resolved 2012-04-01 → 2012-04-30
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31
MCL Health-based Resolved 2011-03-01 → 2011-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Hfpo-Da 0.0053 µg/L 2/4 2024
Pfhxa 0.0032 µg/L 2/4 2024
Pfpea 0.0174 µg/L 2/4 2024
PFOA 0.0040 µg/L 1/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
110.39 µg/L 138%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 124.3 µg/L
58/58 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
66.6 µg/L 111%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 81 µg/L
57/58 SYR4 2012–2019
Copper
389.15 µg/L 30%
of the EPA limit 1300 µg/L
worst single sample: 734 µg/L
20/20 SYR4 2017
Nitrate
1320 µg/L 13%
of the EPA limit 10000 µg/L
20/20 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2023
Atrazine
0.8860 µg/L 30%
of the EPA limit 3 µg/L
worst single sample: 1.12 µg/L
10/32 SYR4 2012–2019
Fluoride
698.9 µg/L 17%
of the EPA limit 4000 µg/L
worst single sample: 737 µg/L
7/7 SYR4 2012–2019
Lead
20.05 µg/L 134%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 24.2 µg/L
6/20 SYR4 2017
Selenium
6.36 µg/L 13%
of the EPA limit 50 µg/L
worst single sample: 6.8 µg/L
3/8 SYR4 2012–2019
Arsenic
2.125 µg/L 21%
of the EPA limit 10 µg/L
worst single sample: 2.2 µg/L
2/8 SYR4 2012–2019
Barium
195.4 µg/L 9.8%
of the EPA limit 2000 µg/L
worst single sample: 198 µg/L
2/8 SYR4 2012–2019
Bromodichloromethane
15.93 µg/L
No EPA limit set
worst single sample: 16.5 µg/L
2/3 SYR4 2012–2014
Chloroform
37.19 µg/L
No EPA limit set
worst single sample: 38.6 µg/L
2/3 SYR4 2012–2014
Dibromochloromethane
2.415 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
2/3 SYR4 2012–2014
Antimony, Total
0.7000 µg/L 12%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.6500 µg/L 11%
of the EPA limit 6 µg/L
1/32 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
1.7 pCi/L 11%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
81 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GRAY, CHARLES
Phone
812-838-2136
Email
[email protected]

Frequently asked questions about Mount Vernon Water Works

Is Mount Vernon Water Works tap water safe to drink?

EPA monitoring detected 22 contaminants in Mount Vernon Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mount Vernon Water Works's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Mount Vernon Water Works serve?

Mount Vernon Water Works reports serving 6,426 people in Indiana, per its EPA record.

Has Mount Vernon Water Works had any water quality violations?

The EPA has 614 violations on file for Mount Vernon Water Works, of which 188 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.