← Indiana

Tap water quality report

Rising Sun Utilities

EPA monitoring tested this supplier for 70 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

70
contaminants tested
11
detected
2,400
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Ohio

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
11
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 1992-12-01 → 1992-12-31
MR Monitoring Resolved 1992-12-01 → 1992-12-31
MR Monitoring Resolved 1992-12-01 → 1992-12-31
MR Monitoring Resolved 1992-12-01 → 1992-12-31
MR Monitoring Resolved 1992-12-01 → 1992-12-31
MR Monitoring Resolved 1992-11-01 → 1992-11-30
MR Monitoring Resolved 1992-11-01 → 1992-11-30
MR Monitoring Resolved 1992-10-01 → 1992-10-31
MR Monitoring Resolved 1992-10-01 → 1992-10-31
MR Monitoring Resolved 1992-10-01 → 1992-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4290 µg/L 43%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
334.45 µg/L 26%
of the EPA limit 1300 µg/L
worst single sample: 352 µg/L
10/10 SYR4 2018
Lead
5.34 µg/L 36%
of the EPA limit 15 µg/L
worst single sample: 6.5 µg/L
9/10 SYR4 2018
TTHM
7.945 µg/L 9.9%
of the EPA limit 80 µg/L
worst single sample: 8.4 µg/L
8/9 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
4.56 µg/L 7.6%
of the EPA limit 60 µg/L
worst single sample: 4.7 µg/L
8/9 SYR4 2012–2019
Lead
0.0069 mg/L 46%
of the EPA limit 0.0150 mg/L
7/7 LCR 2024
Fluoride
518.4 µg/L 13%
of the EPA limit 4000 µg/L
worst single sample: 532 µg/L
2/2 SYR4 2014–2017
Barium
87 µg/L 4.4%
of the EPA limit 2000 µg/L
1/2 SYR4 2014–2017
Cadmium
0.3000 µg/L 6%
of the EPA limit 5 µg/L
1/2 SYR4 2014–2017
Gross Alpha, Excl. Radon And U
1.2 pCi/L 8%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Selenium
1.1 µg/L 2.2%
of the EPA limit 50 µg/L
1/2 SYR4 2014–2017
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HENRY, SCOTT
Phone
812-438-3616
Email
[email protected]

Frequently asked questions about Rising Sun Utilities

Is Rising Sun Utilities tap water safe to drink?

EPA monitoring detected 11 contaminants in Rising Sun Utilities's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Rising Sun Utilities's water?

EPA monitoring detected Nitrate, Copper, Lead, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Rising Sun Utilities serve?

Rising Sun Utilities reports serving 2,400 people in Indiana, per its EPA record.

Has Rising Sun Utilities had any water quality violations?

The EPA has 11 violations on file for Rising Sun Utilities, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.