← Indiana

Tap water quality report

Speedway Water Works

EPA monitoring tested this supplier for 103 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

103
contaminants tested
24
detected
10,578
people served
7
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Marion

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
214
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2003-10-01 → 2003-12-31
MCL Health-based Resolved 2003-10-01 → 2003-12-31
MCL Health-based Resolved 2003-10-01 → 2003-12-31
MCL Health-based Resolved 2003-10-01 → 2003-12-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MCL Health-based Resolved 2002-08-01 → 2002-08-31
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30
MR Monitoring Resolved 2024-04-01 → 2024-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0054 µg/L 5/6 2025
Pfba 0.0180 µg/L 3/6 2025
Pfhxa 0.0040 µg/L 2/6 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
98.99 µg/L 124%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 113.2 µg/L
127/127 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
91.615 µg/L 153%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 133.3 µg/L
112/126 SYR4 2012–2019
Copper
125.6 µg/L 9.7%
of the EPA limit 1300 µg/L
worst single sample: 344 µg/L
35/36 SYR4 2013–2017
Nitrate
1415 µg/L 14%
of the EPA limit 10000 µg/L
worst single sample: 1610 µg/L
34/34 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
Atrazine
1.683 µg/L 56%
of the EPA limit 3 µg/L
worst single sample: 2.71 µg/L
14/31 SYR4 2012–2019
Fluoride
1052.4 µg/L 26%
of the EPA limit 4000 µg/L
worst single sample: 1094 µg/L
14/14 SYR4 2012–2019
Barium
283.65 µg/L 14%
of the EPA limit 2000 µg/L
worst single sample: 294 µg/L
10/13 SYR4 2012–2019
Dibromochloromethane
13.325 µg/L
No EPA limit set
worst single sample: 15.9 µg/L
6/9 SYR4 2012–2019
Bromodichloromethane
22.54 µg/L
No EPA limit set
worst single sample: 24.1 µg/L
5/9 SYR4 2012–2019
Chloroform
74.68 µg/L
No EPA limit set
worst single sample: 79.6 µg/L
5/9 SYR4 2012–2019
Simazine
0.4460 µg/L 11%
of the EPA limit 4 µg/L
worst single sample: 0.4600 µg/L
5/31 SYR4 2012–2019
Chromium
1.1 µg/L 1.1%
of the EPA limit 100 µg/L
4/13 SYR4 2012–2019
Lead
1.79 µg/L 12%
of the EPA limit 15 µg/L
worst single sample: 1.8 µg/L
3/33 SYR4 2013–2017
2,4-D
0.2000 µg/L 0.3%
of the EPA limit 70 µg/L
1/19 SYR4 2012–2019
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
1/13 SYR4 2012–2019
Cyanide
98 µg/L 49%
of the EPA limit 200 µg/L
1/10 SYR4 2015–2019
Cadmium
1.3 µg/L 26%
of the EPA limit 5 µg/L
1/13 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
1.03 µg/L 17%
of the EPA limit 6 µg/L
1/31 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
3.72 pCi/L 25%
of the EPA limit 15 pCi/L
1/1 SYR4 2015
Hexachlorocyclopentadiene
0.1000 µg/L 0.2%
of the EPA limit 50 µg/L
1/31 SYR4 2012–2019
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaArsenicBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, RONNIE E
Phone
317-513-3684
Email
[email protected]

Frequently asked questions about Speedway Water Works

Is Speedway Water Works tap water safe to drink?

EPA monitoring detected 24 contaminants in Speedway Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Speedway Water Works's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Speedway Water Works serve?

Speedway Water Works reports serving 10,578 people in Indiana, per its EPA record.

Has Speedway Water Works had any water quality violations?

The EPA has 214 violations on file for Speedway Water Works, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.