← Indiana

Tap water quality report

Citizens Water - Indianapolis

EPA monitoring tested this supplier for 107 contaminants and detected 34. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

107
contaminants tested
34
detected
880,345
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Marion

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
36
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2020-11-01 → 2020-11-30
MR Monitoring Resolved 2014-07-01 → 2014-07-31
MR Monitoring Resolved 2014-07-01 → 2014-07-31
MR Monitoring Resolved 2014-07-01 → 2014-07-31
MR Monitoring Resolved 2014-07-01 → 2014-07-31
MR Monitoring Resolved 2007-04-01 → 2007-06-30
MR Monitoring Resolved 2007-04-01 → 2007-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0076 µg/L 11/26 2024
Pfhxa 0.0051 µg/L 9/26 2024
PFBS 0.0040 µg/L 3/26 2024
Pfba 0.0057 µg/L 2/26 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
970 µg/L 24%
of the EPA limit 4000 µg/L
worst single sample: 1185 µg/L
891/891 SYR4 2012–2019
Atrazine
1.7 µg/L 57%
of the EPA limit 3 µg/L
worst single sample: 2.8 µg/L
568/1087 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
64.62 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 97.4 µg/L
519/520 SYR4 2012–2019
TTHM
77.34 µg/L 97%
of the EPA limit 80 µg/L
worst single sample: 98.7 µg/L
517/517 SYR4 2012–2019
Dibromochloromethane
4.67 µg/L
No EPA limit set
worst single sample: 7.5 µg/L
284/284 SYR4 2012–2019
Bromodichloromethane
15.09 µg/L
No EPA limit set
worst single sample: 19.9 µg/L
283/283 SYR4 2012–2019
Chloroform
48.285 µg/L
No EPA limit set
worst single sample: 72.7 µg/L
282/282 SYR4 2012–2019
Simazine
0.7820 µg/L 20%
of the EPA limit 4 µg/L
worst single sample: 1.8 µg/L
229/1088 SYR4 2012–2019
Nitrate
2900 µg/L 29%
of the EPA limit 10000 µg/L
worst single sample: 3370 µg/L
216/288 SYR4 2012–2019
Barium
270.2 µg/L 14%
of the EPA limit 2000 µg/L
worst single sample: 300 µg/L
139/139 SYR4 2012–2019
Nitrate-Nitrite
2884 µg/L 29%
of the EPA limit 10000 µg/L
worst single sample: 3370 µg/L
97/132 SYR4 2012–2019
Bromoform
1.15 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
71/284 SYR4 2012–2019
Copper
329.45 µg/L 25%
of the EPA limit 1300 µg/L
worst single sample: 428 µg/L
54/55 SYR4 2018
Chromium
3.34 µg/L 3.3%
of the EPA limit 100 µg/L
worst single sample: 4.4 µg/L
53/139 SYR4 2012–2019
Lead
12.88 µg/L 86%
of the EPA limit 15 µg/L
worst single sample: 35.9 µg/L
45/55 SYR4 2018
Lead
0.0052 mg/L 35%
of the EPA limit 0.0150 mg/L
25/25 LCR 2025
Combined Radium (-226 And -228)
1.706 pCi/L 34%
of the EPA limit 5 pCi/L
worst single sample: 1.73 pCi/L
17/18 SYR4 2016–2019
Gross Alpha, Excl. Radon And U
7.76 pCi/L 52%
of the EPA limit 15 pCi/L
worst single sample: 8.8 pCi/L
17/17 SYR4 2016–2019
2,4-D
1.099 µg/L 1.6%
of the EPA limit 70 µg/L
worst single sample: 2.03 µg/L
15/112 SYR4 2012–2019
Arsenic
3.92 µg/L 39%
of the EPA limit 10 µg/L
worst single sample: 5.6 µg/L
13/139 SYR4 2012–2019
cis-1,2-Dichloroethylene
1 µg/L 1.4%
of the EPA limit 70 µg/L
10/308 SYR4 2012–2019
Combined Uranium
1.34398 µg/L 4.5%
of the EPA limit 30 µg/L
worst single sample: 1.3857 µg/L
9/9 SYR4 2016
Di(2-ethylhexyl) Phthalate
4.528 µg/L 75%
of the EPA limit 6 µg/L
worst single sample: 4.84 µg/L
5/1084 SYR4 2012–2019
Toluene
1.47 µg/L 0.1%
of the EPA limit 1000 µg/L
worst single sample: 1.5 µg/L
4/308 SYR4 2012–2019
Xylenes, Total
2.375 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 2.6 µg/L
4/308 SYR4 2012–2019
Benzo(A)Pyrene
0.0970 µg/L 49%
of the EPA limit 0.2000 µg/L
worst single sample: 0.1000 µg/L
2/967 SYR4 2012–2019
Vinyl Chloride
0.5800 µg/L 29%
of the EPA limit 2 µg/L
worst single sample: 0.6000 µg/L
2/308 SYR4 2012–2019
1,2-Dichloropropane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/308 SYR4 2012–2019
2,4,5-TP
1.21 µg/L 2.4%
of the EPA limit 50 µg/L
1/92 SYR4 2012–2019
Antimony, Total
0.6000 µg/L 10%
of the EPA limit 6 µg/L
1/139 SYR4 2012–2019
73 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane11Cl-PF3OUdS2,3,7,8-TCDD4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CARLSON, CHERYL
Phone
317-429-3569
Email
[email protected]

Frequently asked questions about Citizens Water - Indianapolis

Is Citizens Water - Indianapolis tap water safe to drink?

EPA monitoring detected 34 contaminants in Citizens Water - Indianapolis's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Citizens Water - Indianapolis's water?

EPA monitoring detected Fluoride, Atrazine, Total Haloacetic Acids (HAA5), TTHM, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Citizens Water - Indianapolis serve?

Citizens Water - Indianapolis reports serving 880,345 people in Indiana, per its EPA record.

Has Citizens Water - Indianapolis had any water quality violations?

The EPA has 36 violations on file for Citizens Water - Indianapolis, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.