← Indiana

Tap water quality report

Frankton Water Works

EPA monitoring tested this supplier for 72 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

72
contaminants tested
10
detected
1,800
people served
3
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Madison

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
81
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1994-05-01 → 1994-05-31
MCL Health-based Resolved 1994-05-01 → 1994-05-31
MCL Health-based Resolved 1994-05-01 → 1994-05-31
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
338 µg/L 26%
of the EPA limit 1300 µg/L
worst single sample: 410 µg/L
10/10 SYR4 2018
TTHM
36.08 µg/L 45%
of the EPA limit 80 µg/L
worst single sample: 37.8 µg/L
9/9 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.22 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 14.2 µg/L
8/9 SYR4 2012–2019
Lead
0.0107 mg/L 71%
of the EPA limit 0.0150 mg/L
7/7 LCR 2024
Lead
5 µg/L 33%
of the EPA limit 15 µg/L
worst single sample: 5.1 µg/L
5/10 SYR4 2018
Barium
278 µg/L 14%
of the EPA limit 2000 µg/L
worst single sample: 280 µg/L
2/2 SYR4 2014–2017
Chromium
6 µg/L 6%
of the EPA limit 100 µg/L
2/2 SYR4 2014–2017
Fluoride
892.5 µg/L 22%
of the EPA limit 4000 µg/L
worst single sample: 900 µg/L
2/2 SYR4 2014–2017
Combined Radium (-226 And -228)
0.4100 pCi/L 8.2%
of the EPA limit 5 pCi/L
1/1 SYR4 2018
Gross Alpha, Excl. Radon And U
3.2 pCi/L 21%
of the EPA limit 15 pCi/L
1/1 SYR4 2018
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrateOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PULLEY, KYLE D
Phone
765-635-4251
Email
[email protected]

Frequently asked questions about Frankton Water Works

Is Frankton Water Works tap water safe to drink?

EPA monitoring detected 10 contaminants in Frankton Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Frankton Water Works's water?

EPA monitoring detected Copper, TTHM, Total Haloacetic Acids (HAA5), Lead, Lead, and others. The full list with the level and data source for each is above.

How many people does Frankton Water Works serve?

Frankton Water Works reports serving 1,800 people in Indiana, per its EPA record.

Has Frankton Water Works had any water quality violations?

The EPA has 81 violations on file for Frankton Water Works, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.