← Indiana

Tap water quality report

Indiana American Water - Lowell

EPA monitoring tested this supplier for 104 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
17
detected
11,908
people served
54
health-based violations
Water source
Ground water under surface influence
Ownership
Local government
Counties served
Lake

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

54
health-based violations
287
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2022-12-01 → 2022-12-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31
MCL Health-based Resolved 2019-10-01 → 2019-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
91.98 µg/L 115%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 100.6 µg/L
57/57 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
14.06 µg/L 23%
of the EPA limit 60 µg/L
worst single sample: 15.6 µg/L
57/57 SYR4 2012–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
18/18 LCR 2025
Fluoride
2130 µg/L 53%
of the EPA limit 4000 µg/L
worst single sample: 2200 µg/L
8/8 SYR4 2012–2019
Barium
6.8 µg/L 0.3%
of the EPA limit 2000 µg/L
worst single sample: 7.4 µg/L
7/8 SYR4 2012–2019
Bromodichloromethane
3.35 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
7/8 SYR4 2012–2019
Bromoform
17.8 µg/L
No EPA limit set
worst single sample: 19 µg/L
7/8 SYR4 2012–2019
Dibromochloromethane
8.62 µg/L
No EPA limit set
worst single sample: 9.1 µg/L
7/8 SYR4 2012–2019
Chloroform
1.35 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
6/8 SYR4 2012–2019
Lithium
148 µg/L
No EPA limit set
4/4 UCMR-5 2024
Copper
231.5 µg/L 18%
of the EPA limit 1300 µg/L
worst single sample: 240 µg/L
2/20 SYR4 2017
Chromium
8.46 µg/L 8.5%
of the EPA limit 100 µg/L
worst single sample: 8.7 µg/L
2/8 SYR4 2012–2019
Lead
3.85 µg/L 26%
of the EPA limit 15 µg/L
worst single sample: 4 µg/L
2/20 SYR4 2017
Selenium
6.795 µg/L 14%
of the EPA limit 50 µg/L
worst single sample: 6.8 µg/L
2/8 SYR4 2012–2019
Cyanide
6.5 µg/L 3.3%
of the EPA limit 200 µg/L
1/5 SYR4 2015–2019
Di(2-ethylhexyl) Phthalate
0.7000 µg/L 12%
of the EPA limit 6 µg/L
1/32 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
0.6780 pCi/L 4.5%
of the EPA limit 15 pCi/L
1/1 SYR4 2015
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitrateNitrate-NitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GOSNELL, CHRISTINA
Phone
317-885-2408
Email
[email protected]

Frequently asked questions about Indiana American Water - Lowell

Is Indiana American Water - Lowell tap water safe to drink?

EPA monitoring detected 17 contaminants in Indiana American Water - Lowell's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Indiana American Water - Lowell's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Lead, Fluoride, Barium, and others. The full list with the level and data source for each is above.

How many people does Indiana American Water - Lowell serve?

Indiana American Water - Lowell reports serving 11,908 people in Indiana, per its EPA record.

Has Indiana American Water - Lowell had any water quality violations?

The EPA has 287 violations on file for Indiana American Water - Lowell, of which 54 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.