← Indiana

Tap water quality report

Princeton Water Department

EPA monitoring tested this supplier for 98 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

98
contaminants tested
8
detected
10,875
people served
5
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Gibson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
37
violations on file
5
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1994-11-01 → 1994-11-30
MCL Health-based Resolved 1994-11-01 → 1994-11-30
MCL Health-based Resolved 1994-05-01 → 1994-05-31
MCL Health-based Resolved 1994-05-01 → 1994-05-31
MCL Health-based Resolved 1994-05-01 → 1994-05-31
RPT Monitoring Unaddressed 2025-07-02
RPT Monitoring Unaddressed 2025-07-02
Other Monitoring Resolved 2025-07-01
Other Monitoring Resolved 2025-07-01
Other Monitoring Unaddressed 2024-10-10

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
30.405 µg/L 38%
of the EPA limit 80 µg/L
worst single sample: 34.6 µg/L
34/34 SYR4 2012–2019
Copper
18 µg/L 1.4%
of the EPA limit 1300 µg/L
worst single sample: 19 µg/L
24/30 SYR4 2018
Total Haloacetic Acids (HAA5)
13.16 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 56 µg/L
19/34 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
17/17 LCR 2024
Nitrate
2010 µg/L 20%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
2/2 SYR4 2014–2017
Barium
52.8 µg/L 2.6%
of the EPA limit 2000 µg/L
worst single sample: 53 µg/L
2/2 SYR4 2014–2017
Fluoride
822.5 µg/L 21%
of the EPA limit 4000 µg/L
worst single sample: 850 µg/L
2/2 SYR4 2014–2017
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, CLINT
Phone
812-677-2173
Email
[email protected]

Frequently asked questions about Princeton Water Department

Is Princeton Water Department tap water safe to drink?

EPA monitoring detected 8 contaminants in Princeton Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Princeton Water Department's water?

EPA monitoring detected TTHM, Copper, Total Haloacetic Acids (HAA5), Lead, Nitrate, and others. The full list with the level and data source for each is above.

How many people does Princeton Water Department serve?

Princeton Water Department reports serving 10,875 people in Indiana, per its EPA record.

Has Princeton Water Department had any water quality violations?

The EPA has 37 violations on file for Princeton Water Department, of which 5 are health-based (a contaminant limit or required treatment was breached) and 5 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.