← Indiana

Tap water quality report

Haubstadt Water Department

EPA monitoring tested this supplier for 5 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

5
contaminants tested
5
detected
1,600
people served
15
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Gibson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

15
health-based violations
75
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
71.825 µg/L 90%
of the EPA limit 80 µg/L
worst single sample: 93.8 µg/L
56/56 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
74.8 µg/L 125%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 103.9 µg/L
56/56 SYR4 2012–2019
Copper
42.8 µg/L 3.3%
of the EPA limit 1300 µg/L
worst single sample: 47 µg/L
13/30 SYR4 2016–2018
Lead
0.0044 mg/L 29%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Lead
10.4 µg/L 69%
of the EPA limit 15 µg/L
worst single sample: 12 µg/L
6/30 SYR4 2016–2018

Utility contact

Contact
WEBB, TY
Phone
812-768-5929
Email
[email protected]

Frequently asked questions about Haubstadt Water Department

Is Haubstadt Water Department tap water safe to drink?

EPA monitoring detected 5 contaminants in Haubstadt Water Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Haubstadt Water Department's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Lead, Lead. The full list with the level and data source for each is above.

How many people does Haubstadt Water Department serve?

Haubstadt Water Department reports serving 1,600 people in Indiana, per its EPA record.

Has Haubstadt Water Department had any water quality violations?

The EPA has 75 violations on file for Haubstadt Water Department, of which 15 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.