← Illinois

Tap water quality report

Phil-Aire Estates Mhp

EPA monitoring tested this supplier for 78 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
13
detected
80
people served
9
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Winnebago

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
46
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
MCL Health-based Resolved 2022-01-01 → 2022-03-31
RPT Monitoring Unaddressed 2025-07-02

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
3620 µg/L 36%
of the EPA limit 10000 µg/L
20/22 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Copper
9.52 µg/L 0.7%
of the EPA limit 1300 µg/L
worst single sample: 9.7 µg/L
5/15 SYR4 2013–2019
Nitrate-Nitrite
3353 µg/L 34%
of the EPA limit 10000 µg/L
worst single sample: 3360 µg/L
3/3 SYR4 2012–2015
Barium
1247.75 µg/L 62%
of the EPA limit 2000 µg/L
worst single sample: 1310 µg/L
2/2 SYR4 2014–2017
Bromodichloromethane
0.8053 µg/L
No EPA limit set
worst single sample: 0.8187 µg/L
2/3 SYR4 2012–2017
Dibromochloromethane
0.9862 µg/L
No EPA limit set
worst single sample: 0.9949 µg/L
2/3 SYR4 2012–2017
TTHM
2.28001 µg/L 2.9%
of the EPA limit 80 µg/L
worst single sample: 2.3279 µg/L
2/3 SYR4 2012–2017
Chloroform
0.5143 µg/L
No EPA limit set
1/3 SYR4 2012–2017
Combined Radium (-226 And -228)
1.08 pCi/L 22%
of the EPA limit 5 pCi/L
1/1 SYR4 2015
Dibromoacetic Acid
1 µg/L
No EPA limit set
1/3 SYR4 2012–2017
Fluoride
470 µg/L 12%
of the EPA limit 4000 µg/L
1/2 SYR4 2014–2017
Total Haloacetic Acids (HAA5)
1 µg/L 1.7%
of the EPA limit 60 µg/L
1/3 SYR4 2012–2017
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BUSKER, DARRI
Email
[email protected]

Frequently asked questions about Phil-Aire Estates Mhp

Is Phil-Aire Estates Mhp tap water safe to drink?

EPA monitoring detected 13 contaminants in Phil-Aire Estates Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Phil-Aire Estates Mhp's water?

EPA monitoring detected Nitrate, Lead, Copper, Nitrate-Nitrite, Barium, and others. The full list with the level and data source for each is above.

How many people does Phil-Aire Estates Mhp serve?

Phil-Aire Estates Mhp reports serving 80 people in Illinois, per its EPA record.

Has Phil-Aire Estates Mhp had any water quality violations?

The EPA has 46 violations on file for Phil-Aire Estates Mhp, of which 9 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.