Tap water quality report

Pekin Fed Correctional Inst and Prsncmp

EPA monitoring tested this supplier for 14 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
10
detected
1,635
people served
0
health-based violations
Water source
GWP
Ownership
Federal government
Counties served
Tazewell

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
12
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2023-07-10
Other Monitoring Resolved 2023-07-10
Other Monitoring Resolved 2021-07-01
Other Monitoring Resolved 2021-07-01
Other Monitoring Resolved 2010-07-01
Other Monitoring Resolved 2010-07-01
MR Monitoring Archived 2003-02-01 → 2003-02-28
MR Monitoring Archived 2003-02-01 → 2003-02-28
MR Monitoring Archived 2003-02-01 → 2003-02-28
MR Monitoring Archived 2003-01-01 → 2003-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1500 µg/L 115%
of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 2600 µg/L
71/71 SYR4 2014–2018
Lead
3.585 µg/L 24%
of the EPA limit 15 µg/L
worst single sample: 28 µg/L
44/71 SYR4 2014–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Bromodichloromethane
7.0085 µg/L
No EPA limit set
worst single sample: 7.6 µg/L
8/8 SYR4 2013–2019
Bromoform
6.862 µg/L
No EPA limit set
worst single sample: 6.96 µg/L
8/8 SYR4 2013–2019
Chloroform
2.4295 µg/L
No EPA limit set
worst single sample: 2.65 µg/L
8/8 SYR4 2013–2019
Dibromoacetic Acid
2.453 µg/L
No EPA limit set
worst single sample: 2.46 µg/L
8/8 SYR4 2013–2019
Dibromochloromethane
10.506 µg/L
No EPA limit set
worst single sample: 10.8 µg/L
8/8 SYR4 2013–2019
TTHM
26.48 µg/L 33%
of the EPA limit 80 µg/L
worst single sample: 26.9 µg/L
8/8 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
2.453 µg/L 4.1%
of the EPA limit 60 µg/L
worst single sample: 2.46 µg/L
8/8 SYR4 2013–2019
4 contaminants tested, none detected
Dichloroacetic AcidMonobromoacetic AcidMonochloroacetic AcidTrichloroacetic Acid

Utility contact

Contact
HINSHAW, CLARK
Phone
309-346-8588
Email
[email protected]

Frequently asked questions about Pekin Fed Correctional Inst and Prsncmp

Is Pekin Fed Correctional Inst and Prsncmp tap water safe to drink?

EPA monitoring detected 10 contaminants in Pekin Fed Correctional Inst and Prsncmp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pekin Fed Correctional Inst and Prsncmp's water?

EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Pekin Fed Correctional Inst and Prsncmp serve?

Pekin Fed Correctional Inst and Prsncmp reports serving 1,635 people in Illinois, per its EPA record.

Has Pekin Fed Correctional Inst and Prsncmp had any water quality violations?

The EPA has 12 violations on file for Pekin Fed Correctional Inst and Prsncmp, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.